Contrast enhanced spectral mammography versus automated breast ultrasound in the local staging of breast cancer /
Rana Hussein Mostafa Mousa Khaled
Contrast enhanced spectral mammography versus automated breast ultrasound in the local staging of breast cancer / التصوير الشعاعى للثدى بالصبغة مقارنة بالموجات فوق الصوتية الآلية في تحديد مرحلة الإنتشار الموضعى لسرطان الثدى Rana Hussein Mostafa Mousa Khaled ; Supervised Maha Hussein Helal , Omar Zakaria Youssef , Sahar Mahmoud Mansour - Cairo : Rana Hussein Mostafa Mousa Khaled , 2018 - 109 P. : charts , facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
Purpose To compare contrast enhanced spectral mammography and automated breast ultrasound with regards to cancer size, extension and multiplicity in reported cases with breast cancer.Patients and methods Patient informed consent was obtained from 60 patients with proved breast cancer. ABUS was done for anteroposterior; lateral and medial acquisitions and CESM performed using low and high energy exposures in craniocaudal and mediolateral oblique views after IV injection of contrast agent. Included breast cancers were analyzed regarding disease extension, size, and multiplicity. Operative data were the gold standard reference. Conclusion ABUS is a non-invasive alternative tool to CESM in the local staging of breast cancer. ABUS was non-inferior to CESM in the evaluation of cancer size. ABUS is more accurate in determining parenchymal infiltration and CESM is better in detection of multiplicity.Clinical Relevance/Application ABUS is considered a revolution in breast scanning by ultrasound imaging that can be used as a non-invasive, fast and easy tool of breast imaging in early detection (in other words; screening) and local staging of breast carcinomas
Breast Cancer Mammography Ultrasound
Contrast enhanced spectral mammography versus automated breast ultrasound in the local staging of breast cancer / التصوير الشعاعى للثدى بالصبغة مقارنة بالموجات فوق الصوتية الآلية في تحديد مرحلة الإنتشار الموضعى لسرطان الثدى Rana Hussein Mostafa Mousa Khaled ; Supervised Maha Hussein Helal , Omar Zakaria Youssef , Sahar Mahmoud Mansour - Cairo : Rana Hussein Mostafa Mousa Khaled , 2018 - 109 P. : charts , facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
Purpose To compare contrast enhanced spectral mammography and automated breast ultrasound with regards to cancer size, extension and multiplicity in reported cases with breast cancer.Patients and methods Patient informed consent was obtained from 60 patients with proved breast cancer. ABUS was done for anteroposterior; lateral and medial acquisitions and CESM performed using low and high energy exposures in craniocaudal and mediolateral oblique views after IV injection of contrast agent. Included breast cancers were analyzed regarding disease extension, size, and multiplicity. Operative data were the gold standard reference. Conclusion ABUS is a non-invasive alternative tool to CESM in the local staging of breast cancer. ABUS was non-inferior to CESM in the evaluation of cancer size. ABUS is more accurate in determining parenchymal infiltration and CESM is better in detection of multiplicity.Clinical Relevance/Application ABUS is considered a revolution in breast scanning by ultrasound imaging that can be used as a non-invasive, fast and easy tool of breast imaging in early detection (in other words; screening) and local staging of breast carcinomas
Breast Cancer Mammography Ultrasound