Study of some biophysical properities of R.B.Cs during cardiopulmonary bypass (C.P.B) with different flows / (Record no. 14169)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 032840000a22003610004500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GICUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223025506.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 061120s2004 ua a f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GICUC |
Language of cataloging | eng |
Transcribing agency | EG-GICUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | Eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.12.04.M.Sc.2004.Ha.S |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Hany Desokey Masuad Awad |
245 10 - TITLE STATEMENT | |
Title | Study of some biophysical properities of R.B.Cs during cardiopulmonary bypass (C.P.B) with different flows / |
Statement of responsibility, etc. | Hany Desokey Masuad Awad ; supervised Anwar Abd El azeem Elsayed , Fawiza Mohmed Abu ELFotouh , Maha Anwar Ali |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دراسة الخواص البيوفيزيائية لكرات الدم الحمراء اثناء تحويلة القلب الرئوية عند تدفقات دموية مختلفة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Hany Desokey Masuad Awad , |
Date of publication, distribution, etc. | 2004 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 96P : |
Other physical details | ill , diagrs ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty Of Science - Department Of Biophysics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Cardiopulmonary bypass (CPB) is a safe support system during major cardiac operations because it allows the distribution of adequately oxygenated blood to the entire bodyThe optimal perfusion flow to be used during hypothermic CPB remains a controversial issueIn the present study , the effect of different flows and pressures on oxygen delivery , content and consumption , hemoglobin (Hb) concentration and Hb affinity for O2 , red blood cell membrane properties and morphology as well as dielectric properties of the red cells was comparedSuch an effect was evaluated for sixty patients undergoing open - heart surgery using CPB (membrane oxygenator) and systemic hypothermiaThe combined applications of these techniques allowed us to describe accurately the effects of different flows on human erythrocytes in terms of morphological and functional parametersThe patients were randomized into two groups (30 each) according to the flow and pressure (low flow , low pressure and high flow , high pressure) , and erythrocyte samples for both groups were taken at different time intervals (before - , during and post - CPB) No significant change of the mentioned properties for low flow group , the flow rate was kept at 30 ml / kg / min and the pressure at 40 - 60 mmHg at 28O C , was recorded (p 005) while the properties of the high flow group , the flow rate was kept at 50 ml / kg / min at 28O C and the arterial pressure was 60 - 80 mmHg , were greatly affected by the time of operationHence , low flow can be safely used in young patients without any organ impairment or carotid artery disease , while high flow should be used for patients with any organ dysfunction , at the initiation of CPB and during rewarming to compensate for the increase in oxygen consumption and the needs for better perfusion pressure |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Biophysical properities |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cardiopulmonary bypass |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Different flows |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | R.B.Cs |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Anwar Abd El azeem Elsayed , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Fawiza Mohmed Abu ELFotouh , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Maha Anwar Ali , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Enas |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Mustafa |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type |
---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.04.M.Sc.2004.Ha.S | 01010110043669000 | 22.09.2023 | Thesis | |
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.04.M.Sc.2004.Ha.S | 01020110043669000 | 22.09.2023 | CD - Rom |