header

The effect of implant number splinted on stress distribution under mandibular overdenture / (Record no. 14569)

MARC details
000 -LEADER
fixed length control field 01516nam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223025517.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 090202s2008 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2008.No.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nora Mohamed Sheta
245 14 - TITLE STATEMENT
Title The effect of implant number splinted on stress distribution under mandibular overdenture /
Statement of responsibility, etc. Nora Mohamed Sheta ; supervised Khaled A. Zekry , Essam A. Aziz
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير عدد الغرسات المترابطة على توزيع الأحمال أسفل الأطقم السفلية المحمولة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nora Mohamed Sheta ,
Date of publication, distribution, etc. 2008
300 ## - PHYSICAL DESCRIPTION
Extent 111 Leaves :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. This study was carried out to evaluate the effect of implants number on the stress distribution under implant-supported overdentures using strain gauge technology.An acrylic model of a completely edentulous lower arch was constructed
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mandibular overdenture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Number of implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Splinted
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Aadelaziz ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Ahmed Zekry ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Fatma
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2008.No.E 01010110050584000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2008.No.E 01020110050584000 22.09.2023 CD - Rom 50584.CD