A Comparative Study Between The Accuracy Of 10 Mhz And 15 Mhz Ultrasound Probes For Retinal Evaluation In Silicone Oil Filled Globes / (Record no. 167618)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 06311namaa2200433 i 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - أخر تعامل مع التسجيلة | |
control field | 20250223033252.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 240708s2023 ua a|||f |m|| 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloguing agency | EG-GICUC |
Transcribing agency | EG-GICUC |
Modifying agency | EG-GICUC |
Description conventions | rda |
Language of cataloging | eng |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
Language code of summary or abstract | eng |
-- | ara |
049 ## - Acquisition Source | |
Acquisition Source | Deposit |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 617.73 |
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
Classification number | 617.73 |
Edition number | 21 |
097 ## - Degree | |
Degree | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Local Call Number | Cai01.11.24.Ph.D.2023.Ma.C. |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Authority record control number or standard number | Maha Al Sayed Al Badawi Ibrahim Abdulaaty, |
Preparation | preparation. |
245 10 - TITLE STATEMENT | |
Title | A Comparative Study Between The Accuracy Of 10 Mhz And 15 Mhz Ultrasound Probes For Retinal Evaluation In Silicone Oil Filled Globes / <br/><br/> |
Statement of responsibility, etc. | by Maha Al Sayed Al Badawi Ibrahim Abdulaaty; Noha Mahmoud Mohamed Khalil, Riham Samy Hanafy Mahmoud Allam, Iman Magdi Eissa |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دراسة مقارنة بين دقة مجسات جهاز الموجات فوق الصوتية ذات تردد ال10 ميجاهيرتز و ال 15 يجاهيرتز في تقييم الشبكية بالعيون الممتلئة بزيت السيليكون / |
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Date of production, publication, distribution, manufacture, or copyright notice | 2023. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 98 pages : |
Other physical details | illustrations ; |
Dimensions | 25 cm. + |
Accompanying material | CD. |
336 ## - CONTENT TYPE | |
Content type term | text |
Source | rda content |
337 ## - MEDIA TYPE | |
Media type term | Unmediated |
Source | rdamedia |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
Source | rdacarrier |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.)-Cairo University, 2023. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Referernces: pages 89-98. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Purpose: To compare 10-MHz and15-MHz B-scan probes regarding detection and localization of retinal detachment (RD) in silicone-oil-filled eyes. <br/> <br/>Methods: This cross-sectional observational study included 100 eyes (98 patients) -having media opacity precluding fundus examination- scheduled for silicone-oil removal. Patients were examined in the sitting-position using both frequencies one week preoperatively. Longitudinal and transverse scans were taken in primary-gaze, inferior, inferonasal and inferotemporal positions to detect the presence/absence and extent of RD. Patients were sub-grouped according to axial lengths (AXLs), state of silicone emulsification and globe filling. Agreement between sonographic and intraoperative observations was compared. <br/> <br/>Results: No statistically significant differences were found between 15-MHz and intra-operative findings regarding RD detection (P=0.752) and accurate localization of inferior, inferonasal and inferotemporal RD (P=0.279, 0.606 and 0.599).There were statistically significant differences between 10-MHz and intra-operative findings regarding RD detection and localization (P<0.001).The 15-MHz probe was superior to 10-MHz probe regarding accuracy of RD detection and localization (94% and 47% respectively). The accuracy of 15-MHz probe was 88%, 83% and 85% in detecting and localizing inferior, inferonasal and inferotemporal RD compared to 45%, 60% and 62% with 10-MHz probe. The 15-MHz probe showed better sensitivity while 10-MHz probe showed better accuracy in eyes with short AXLs. The 10-MHz probe showed better sensitivity in patients with sonographic emulsification while15-MHz probe had better sensitivity in detecting vitreoretinal-interface disorders. <br/>Conclusion: The 15-MHz B-scan probe is more accurate in detecting and localizing recurrent RD in silicone-oil-filled globes with higher sensitivity in detecting vitreoretinal-interface disorders. <br/> |
520 ## - SUMMARY, ETC. | |
Summary, etc. | كما أظهرت النتائج أيضاً ز يا دة حساسية مجس الموجات فوق الصوتية ذي ترد د ال 15 ميجاهرتزكلما قل الطول المحوري للعين ؛ حي ث كانت أعلى في المرضى الذين يعانون من طول النظرالمحوري عنالمرضى أصحاب طول العين الطبيعي و المرضى الذين يعانون من قصرالنظرالمحوري. <br/> <br/> في حي ن أظهر مجس الموجات فوق الصوتية ذو تردد ال 10 ميجاهرتز تحسنًا في الدقة و القيمة التنبؤية الإيجابية في المرضى الذين يعانون من طول النظرالمحوري مقارنةً بـالمرضى أصحاب الطول الطبيعي للعينو الذين يعانون من قصرالنظر المحوري. <br/> <br/> و قد أظهر مجس الموجات فوق الصوتية ذو تردد ال 10 ميجاهرتز نتائجاً أكثر دقة فيما يتعلقبالحساسية و القيمة التنبؤية السلبية في المرضى الذين يعانون من تحلل زيت السيليكون. <br/> <br/> كما أظهر كلا المجسين نتائجاً أكثر دقة فيما يتعلق بالحساسية و القيمة التنبؤية الإيجابية في المرضى الذين يعانون من عدم اكتمال امتلاء العين بزيت السيليكون. <br/> <br/> و توصي هذه الدراسة باستخدام مجس الموجات فوق الصوتية ذي تردد ال 15 ميجاهيرتز في تصويرالعيون الممتلئة بزيت السيليكون والذين يعانون من وجود عتامات تعوق الفحص الإكلينيكي لشبكية العين. وينصح بإجراء الفحص في وضع الجلوس للإستفادة من الدقة العالية لهذا المجس في تصويرالجزء الأسفللشبكية العين, حيث كشفت نتائج الدراسة أن دقة مجس الموجات فوق الصوتية ذي تردد ال 15 ميجاهرتز ف يتشخي ص الانفصال الشبكي كان ت بنسبة 94٪ مقارنة بدقة لا تتجاوز ال 47٪ لمجس الموجات فوق الصوتيةذي تردد ال 10 ميجاهرتز. <br/> |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Issues CD | Issued also as CD |
546 ## - LANGUAGE NOTE | |
Text Language | Text in English and abstract in Arabic & English. |
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | retinal detachment |
Source of heading or term | qrmak |
653 #0 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | silicone-oil |
-- | ultrasound |
-- | 10-MHz |
-- | 15-MHz |
-- | B-scan |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Noha Mahmoud Mohamed Khalil |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Riham Samy Hanafy Mahmoud Allam |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Iman Magdi Eissa |
Relator term | thesis advisor. |
900 ## - Thesis Information | |
Grant date | 2023 |
Supervisory body | Noha Mahmoud Mohamed Khalil |
-- | Riham Samy Hanafy Mahmoud Allam |
-- | Iman Magdi Eissa |
Universities | Cairo University |
Faculties | Faculty of Medicine |
Department | Department of Ophthalmology |
905 ## - Cataloger and Reviser Names | |
Cataloger Name | Eman El gebaly |
Reviser Names | Huda |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Edition | 21 |
Suppress in OPAC | No |
Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 08.07.2024 | 88448 | Cai01.11.24.Ph.D.2023.Ma.C. | 01010110088448000 | 08.07.2024 | 08.07.2024 | Thesis |