A Comparison Of Passive Fit Between Conventional And Digital Impression Techniques For An All-On-6 Maxillary Framework : (Record no. 167985)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 08111namaa22004331i 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - أخر تعامل مع التسجيلة | |
control field | 20250223033300.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 240923s2023 |||a|||f |m|| 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloguing agency | EG-GICUC |
Language of cataloging | eng |
Transcribing agency | EG-GICUC |
Modifying agency | EG-GICUC |
Description conventions | rda |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
Language code of summary or abstract | eng |
-- | ara |
049 ## - Acquisition Source | |
Acquisition Source | Deposit |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 617.6 |
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
Classification number | 617.6 |
Edition number | 21 |
097 ## - Degree | |
Degree | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Local Call Number | Cai01.09.13.M.Sc.2023.Ha.C. |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Authority record control number or standard number | Hasnaa El-Tablawy, |
Preparation | preparation. |
245 10 - TITLE STATEMENT | |
Title | A Comparison Of Passive Fit Between Conventional And Digital Impression Techniques For An All-On-6 Maxillary Framework : |
Remainder of title | An Invitro Study / |
Statement of responsibility, etc. | By Hasnaa El-Tablawy; Under the supervision of Dr.Amal Kaddah, Dr. Mohamed Farouk, Dr. Nouran Abd Elnaby |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | مقارنة بين التوافق السلبي بين تقنيات الانطباع التقليدية والرقمية لإطار شامل للفك العلوي على 6 غرسات : |
Remainder of title | دراسه معمليه / |
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Date of production, publication, distribution, manufacture, or copyright notice | 2023. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 121 pages : |
Other physical details | illustrations ; |
Dimensions | 25 cm. + |
Accompanying material | CD. |
336 ## - CONTENT TYPE | |
Content type term | text |
Source | rda content |
337 ## - MEDIA TYPE | |
Media type term | Unmediated |
Source | rdamedia |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
Source | rdacarrier |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) -Cairo University, 2023. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliography: pages 94-112. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Title of the research in English:<br/>A comparison of passive fit between conventional and digital impression techniques for an all-on-6 maxillary framework: An in-vitro study. <br/>Aim of performing the research:<br/>To compare the passive fit of an implant supported framework fabricated using conventional open tray impression versus the digital impression using intraoral scanner for 6 parallel implants restoring edentulous maxilla.<br/>Scientific procedures:<br/>Six implants were installed in an epoxy edentulous cast using trial denture base set up of teeth. All implants were installed using dental surveyor to ensure parallelism of all 6 implants, installed in central, canine, and second premolar areas bilaterally.<br/>In this invitro study ten frameworks were fabricated. <br/> In Group 1: Five Splinted open tray conventional Impressions were carried out for all the six installed implants; each impression was poured in a conventional manner to obtain a master cast. This master cast was used for fabrication of a casted superstructure framework. <br/>Group 2: Scan bodies were screwed to all of the installed implants, and five digital impressions using an intra-oral scanner were carried out. The STL files of the five impressions were used to fabricate 5 milled superstructure framework using exocad software.<br/>Passive fit of all frameworks fabricate in the two groups was evaluated in the present invitro study using two methods; the first method is the Sheffield test and that would be assessed as passive or non-passive, and the second method was measuring the gap distance using stereomicroscope when all screws were fully tightened and when only the most distal implant was fully tightened in each implant in each constructed framework.<br/>Outcome measures:<br/>There was no statistically significant difference between the two groups when all screws were fully tightened, while there was statistical significance difference between the two groups when only the most distal implant was fully tightened, results showed more passive fit in casted group compared to milled group.<br/>Conclusion:<br/>From the results of the current study, we concluded that:<br/>Absolute passive fit cannot be achieved regardless of the type of material and technique used. Further evaluation of the reliability and accuracy of the digital impression approach must be undertaken in both laboratory and clinical settings. <br/>When evaluating the passive fit of an implant supported full arch maxillary framework fabricated using conventional and digital technique, there was a statistically significant higher vertical gap distance for the digitally fabricated milled framework when compared to the conventional casted framework |
520 ## - SUMMARY, ETC. | |
Summary, etc. | الهدف من إجراء البحث :<br/>مقارنة التوافق السلبي للإطار المدعوم بغرسات الاسنان المصنوع باستخدام انطباع تقليدي مقابل الانطباع الرقمي باستخدام ماسح ضوئي داخل الفم لـ 6 غرسات متوازية لاستعادة الفك العلوي عديم الاسنان.<br/>الاجراءات العلميه : <br/>تم تثبيت ستة غرسات في قالب إيبوكسي عديم الأسنان باستخدام قاعدة أسنان تجريبية. تم تثبيت جميع الغرسات باستخدام مساح الأسنان لضمان التوازي لجميع الغرسات الستة ، المثبتة في المناطق المركزية ، والكلاب ، والضاحك الثاني بشكل ثنائي<br/>في هذه الدراسة تم تصنيع عشرة أطر.<br/> في المجموعة 1: تم تنفيذ الانطباعات التقليدية الخمس ذات الدرج المفتوح لجميع الغرسات الست المثبتة ، وتم سكب كل انطباع بطريقة تقليدية للحصول على قالب رئيسي. تم استخدام هذا المصبوب الرئيسي لتصنيع هيكل فوقي مصبوب.<br/>المجموعة 2: تم ربط أجسام المسح بجميع الغرسات المثبتة ، وتم إجراء خمس طبعات رقمية باستخدام ماسح ضوئي داخل الفم من نوع ميديت اي 500. تم استخدام ملفات STL للطبعات الخمسة لتصنيع 5 إطار عمل للبنية الفوقية باستخدام برنامج الاكسوكاد.<br/>تم تقييم التوافق السلبي لجميع الأطر المصنعة في المجموعتين في الدراسه المعمليه الحالية باستخدام طريقتين ؛ الطريقة الأولى هي اختبار شيفيلد والذي سيتم تقييمه على أنه سلبي أو غير سلبي ، والطريقة الثانية كانت قياس مسافة الفجوة باستخدام المكروسكوب المجسم عندما تكون جميع المسامير مربوطه بالكامل وعندما يتم ربط الزرعة الأبعد فقط في كل غرسة في كل إطار مبني.<br/>مقاييس النتائج : <br/>لم يكن هناك فرق ذو دلالة إحصائية بين المجموعتين عندما تم ربط جميع المسامير بشكل كامل ، بينما كان هناك فرق دلالة إحصائية بين المجموعتين عندما تم تشديد الزرع الأبعد فقط ، وأظهرت النتائج ملاءمة أكثر سلبية في المجموعة المصبوبة مقارنة بالمجموعة المصنوعه باستخدام الماسح الضوئي<br/>الخلاصه :<br/>من نتائج الدراسة الحالية يمكننا ان نلخص ما يلي:<br/>1. لا يمكن تحقيق التوافق السلبي المطلق بغض النظر عن التقنية المستخدمة.<br/>2. قد لا يكون نهج الانطباع الرقمي الذي يستخدم الماسحات الضوئية داخل الفم دقيقًا مثل انطباعات مستوى الغرسة التقليدية لإنشاء ملاءمة مقبولة في عمليات تصنيع إطار الزرع طويل المسافه.<br/>3. أظهرت الأطر المصبوبة ملاءمة سلبية أفضل مقارنة بالأطر المصنوعه باستخدام الماسح الضوئي<br/> |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Issues CD | Issued also as CD |
546 ## - LANGUAGE NOTE | |
Text Language | Text in English and abstract in Arabic & English. |
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Dentistry |
Source of heading or term | qrmak |
653 #0 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | implant |
-- | full arch |
-- | casted framework |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amal Kaddah |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohamed Farouk |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nouran Abd Elnaby |
Relator term | thesis advisor. |
900 ## - Thesis Information | |
Grant date | 01-01-2023 |
Supervisory body | Amal Kaddah |
-- | Mohamed Farouk |
-- | Nouran Abd Elnaby |
Discussion body | Iman Taftazani |
-- | Maha Wagdy El-Kardawy |
Universities | Cairo University |
Faculties | Faculty of Dentistry |
Department | Department of Implantology |
905 ## - Cataloger and Reviser Names | |
Cataloger Name | Nourhan |
Reviser Names | Huda |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Edition | 21 |
Suppress in OPAC | No |
Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 23.09.2024 | 88481 | Cai01.09.13.M.Sc.2023.Ha.C. | 01010110088481000 | 23.09.2024 | 23.09.2024 | Thesis |