header

Clinical evaluation of self- adhesive bulk-fill resin composite versus conventionally bonded bulk-fill resin composite in restoration of proximal lesions over a period of 18 months follow-up : (Record no. 170077)

MARC details
000 -LEADER
fixed length control field 08934namaa22004211i 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - أخر تعامل مع التسجيلة
control field 20250223033406.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250108s2023 |||a|||f m||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.605
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 617.605
Edition number 21
097 ## - Degree
Degree Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.09.03.Ph.D.2023.Mo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Mohamed Mohamed Sabry Mohamed,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Clinical evaluation of self- adhesive bulk-fill resin composite versus conventionally bonded bulk-fill resin composite in restoration of proximal lesions over a period of 18 months follow-up :
Remainder of title A Randomized Clinical Trial /
Statement of responsibility, etc. by Mohamed Mohamed Sabry Mohamed ; supervision of: Dr.Omaima Mohamed Safwat,Dr. Dina Mounir El kady.
246 15 - VARYING FORM OF TITLE
Title proper/short title : التقییم السریري لمركب الراتنج ذاتي اللصق كتلي الملء مقابل مركب الراتنج كتلي الملء ذو اللصق التقلیدي في ترمیم الآفات المُتاخمة على مدى 18 شھرًا من المتابعة
Remainder of title / تجربة سریریة عشوائیة
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2023.
300 ## - PHYSICAL DESCRIPTION
Extent 108 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D)-Cairo University, 2023.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 103-107.
520 ## - SUMMARY, ETC.
Summary, etc. Aim: The current clinical investigation aimed to compare and contrast the clinical efficacy of self- adhesive bulk fill resin composite and traditionally bonded bulk fill resin composite in the restoration of proximal lesions during the course of 18 months.<br/>Methodology: In a parallel study design, forty participants with carious proximal lesions were assigned at random to the intervention (Surefil-one) and comparison (bulk-fill) groups. All ingredients were used in accordance with the directions provided by the manufacturer. Two blinded assessors evaluated restorations at initial screening (one week), six months, twelve months, and 18 months using modified USPHS criteria measuring (marginal adaption, marginal discoloration, surface roughness, anatomic form, postoperative sensitivity, recurrent caries, and retention analysis). <br/><br/>Results: Intergroup comparisons of both materials revealed no differences of statistical significance in marginal adaptation (P = 0.0952), recurrent caries (P = 0.8728), postoperative sensitivity (P = 0.5936), or retention analysis (P = 0.3173). whereas there was a difference of statistical significance between both materials for marginal discoloration after 18 months (P = 0.0235), surface roughness after 12 and 18 months (P = 0.0013 and P = 0.0001 respectively), and anatomic form after 18 months (P = 0.0023).<br/>Conclusions: Over an 18-month test time frame, self-adhesive bulk-fill resin composite hybrid (surefil-one) revealed clinically less satisfying performance when compared to traditionally bonded bulk-fill resin composite.
520 ## - SUMMARY, ETC.
Summary, etc. ﻓﻲ ﺗﺼﻤﯿﻢ اﻟﻔﻢ اﻟﻤﻮازي ، ﺗﻢ أﺧﺘﯿﺎر أرﺑﻌﻮن ﻣﺸﺎر ًﻛﺎ ﯾﻌﺎﻧﻮن ﻣﻦ آﻓﺎت ﻣﺘﺎﺧﻤﺔ )ﻣﻦ اﻟﺪرﺟﺔ اﻟﺜﺎﻧﯿﺔ( ﺑﺸﻜﻞ ﻋﺸﻮاﺋﻲ وﺗﻢ ﺗﺮﻣﯿﻢ ﻋﺪد<br/>ﻋﺸﺮون ﻓﺠﻮة ﺑﺄﺳﺘﺨﺪام ﻛﺒﺴﻮﻻت ﺗﺤﺘﻮي ﻋﻠﻰ ﻣﺮﻛﺐ راﺗﻨﺞ ذاﺗﻲ اﻟﻠﺼﻖ ﻛﺘﻠﻲ اﻟﻤﻠﺊ و ﺗﻢ أﺳﺘﺨﺪام ﻣﺮﻛﺐ اﻟﺮاﺗﻨﺞ ﻛﺘﻠﻲ اﻟﻤﻠﺊ ذو<br/>اﻟﻠﺼﻖ اﻟﺘﻘﻠﯿﺪي ﻓﻲ ﻋﺸﺮون ﻓﺠﻮة أﺧﺮى , ﺗﻢ اﺳﺘﺨﺪام ﺟﻤﯿﻊ اﻟﻤﻮاد وﻓﻘًﺎ ﻟﺘﻌﻠﯿﻤﺎت اﻟﺸﺮﻛﺎت اﻟﻤﺼﻨﻌﺔ. ﺗﻢ ﺗﻘﯿﯿﻢ اﻟﺘﺮﻣﯿﻤﺎت ﺑﺎﻟﻨﺴﺒﺔ اﻟﺘﻜﯿﻒ اﻟﮭﺎﻣﺸﻲ ، ﺗﻐﯿﺮ اﻟﻠﻮن اﻟﮭﺎﻣﺸﻲ ، ﺧﺸﻮﻧﺔ اﻟﺴﻄﺢ ، اﻟﺸﻜﻞ اﻟﺘﺸﺮﯾﺤﻲ ، ﺣﺴﺎﺳﯿﺔ ﻣﺎ ﺑﻌﺪ اﻟﺠﺮاﺣﺔ ، اﻟﺘﺴﻮس اﻟﻤﺘﻜﺮر ، وﺗﺤﻠﯿﻞﺑﻘﺎء<br/>اﻟﺤﺸﻮة وﺗﻤﺎﺳﻜﮭﺎ ﻋﻨﺪ ﺑﺪء اﻟﺪراﺳﺔ )أﺳﺒﻮع واﺣﺪ(،.ﺑﻌﺪ ﺳﺘﺔ أﺷﮭﺮ ، ﺑﻌﺪ ۲۱ ﺷﮭ ًﺮا ، وﺑﻌﺪ ۸۱ ﺷﮭ ًﺮا ﺑﻮاﺳﻄﺔ ﻟﺠﻨﺔ ﺗﻘﯿﯿﻢ ﻣﺪرﺑﺔ طﺒﻘﺎ<br/>ﻟﻨﻈﺎم اﻟﺘﻘﯿﯿﻢ اﻟﻤﻌﺪل اﻟﺨﺎص ﺑﺎﻟﺼﺤﺔ اﻟﻌﺎﻣﺔ ﻓﻲ اﻟﻮﻻﯾﺎت اﻟﻤﺘﺤﺪة اﻻﻣﺮﯾﻜﯿﺔ criteria) USPHS .(Modified<br/><br/>ﺗﻢ إﺟﺮاء ﻣﻘﺎرﻧﺎت ﺑﯿﻦ اﻟﻤﺠﻤﻮﻋﺎت ﺑﯿﻦ اﻟﺘﺪﺧﻼت ﺑﺎﺳﺘﺨﺪام اﺧﺘﺒﺎر Chi-Squared ﺑﻤﺴﺘﻮى دﻻﻟﺔ إﺣﺼﺎﺋﻲ ﻣﺤﺪد ﻋﻨﺪ )٥۰٫۰ (P=<br/> ، وأﺟﺮﯾﺖ ﻣﻘﺎرﻧﺎت ﺑﯿﻦ اﻟﻤﺠﻤﻮﻋﺎت داﺧﻞ ﻛﻞ ﺗﺪﺧﻞ ﺑﺎﺳﺘﺨﺪام اﺧﺘﺒﺎر Chi-Squared ﻣﻊ ﻣﺴﺘﻮى دﻻﻟﺔ إﺣﺼﺎﺋﻲ ﻣﺤﺪد ﻋﻨﺪ )۳۸۰۰٫۰(P= ﺑﻌﺪ ﺗﺼﺤﯿﺢ Bonferroni . ﺑﻌﺪ ۸۱ ﺷﮭ ًﺮا ، ﻟﻢ ﺗﻈﮭﺮ اﻟﻤﻘﺎرﻧﺔ ﺑﯿﻦ اﻟﻤﺠﻤﻮﻋﺎت ﺑﯿﻦ ﻛﻠﺘﺎ اﻟﻤﺎدﺗﯿﻦ أي ﻓﺮق ﻣﻌﺘﺪ ﺑﮫ<br/>إﺣﺼﺎﺋﯿﺎ ﻟﻠﺘﻜﯿﻒ اﻟﮭﺎﻣﺸﻲ ) ۲٥۹۰٫۰(P= ، واﻟﺘﺴﻮس اﻟﻤﺘﻜﺮر )۸۲۷۸۰٫۰(P= ، وﺣﺴﺎﺳﯿﺔ ﻣﺎ ﺑﻌﺪ اﻟﺠﺮاﺣﺔ )٦۳۹٥٫۰(P= ،<br/>وﺗﺤﻠﯿﻞ اﻻﺣﺘﻔﺎظ )۳۷۱۳٫۰.(P= ﺑﯿﻨﻤﺎ ﻛﺎن ھﻨﺎك ﻓﺮق ذو دﻻﻟﺔ إﺣﺼﺎﺋﯿﺔ ﺑﯿﻦ ﻛﻠﺘﺎ اﻟﻤﺎدﺗﯿﻦ ﻟﻠﺘﻐﯿﺮ اﻟﮭﺎﻣﺸﻲ ﺑﻌﺪ ۸۱ ﺷﮭ ًﺮا<br/>)٥۳۲۰٫۰(P= وﺧﺸﻮﻧﺔ اﻟﺴﻄﺢ ﺑﻌﺪ ۲۱ و ۸۱ ﺷﮭ ًﺮا )۳۱۰۰٫۰P= و ۱۰۰۰٫۰P= ﻋﻠﻰ اﻟﺘﻮاﻟﻲ( واﻟﺸﻜﻞ اﻟﺘﺸﺮﯾﺤﻲ ﺑﻌﺪ 18 ﺷﮭ ًﺮا )۳۲۰۰٫۰.(P= ﻓﯿﻤﺎ ﯾﺘﻌﻠﻖ ﺑﺎﻷداء اﻟﺴﺮﯾﺮي ، أظﮭﺮت ﻛﻠﺘﺎ اﻟﻤﺎدﺗﯿﻦ ا\ درﺟﺎت ﻣﻘﺒﻮﻟﺔ ﺳﺮﯾﺮﯾﺎ ﻓﻲ ﻏﺎﻟﺒﯿﺔ اﻟﻤﻌﺎﯾﯿﺮ )ﺑﺎﺳﺘﺜﻨﺎء اﻟﺘﺮﻣﯿﻤﺎت<br/>اﻟﻔﺎﺷﻠﺔ.(<br/><br/>اﻟﺨﻼﺻﺔ:<br/>ﻓﻲ ظﻞ ﻗﯿﻮد اﻟﺪراﺳﺔ اﻟﺤﺎﻟﯿﺔ ﯾﻤﻜﻦ اﺳﺘﺨﻼص اﻻﺳﺘﻨﺘﺎﺟﺎت اﻟﺘﺎﻟﯿﺔ:<br/>۱. ﻋﻨﺪ ﻣﻘﺎرﻧﺘﮭﺎ ﺑﻤﺮﻛﺐ اﻟﺮاﺗﻨﺞ ﻛﺘﻠﻲ اﻟﻤﻠﺊ ذو اﻟﻠﺼﻖ اﻟﺘﻘﻠﯿﺪي، أظﮭﺮ ﻣﺮﻛﺐ اﻟﺮاﺗﻨﺞ ذاﺗﻲ اﻟﻠﺼﻖ ﻛﺘﻠﻲ اﻟﻤﻠﻲء أداء أﻗﻞ إرﺿﺎء<br/>ﺳﺮﯾﺮﯾﺎ ﺧﻼل ﻓﺘﺮة اﺧﺘﺒﺎر ﻣﺪﺗﮭﺎ ۸۱ ﺷﮭ ًﺮا.<br/><br/>۲. ۲. ﻧﻈ ًﺮا ﻟﺒﻌﺾ اﻟﻤﺨﺎوف ﻓﻲ اﻟﻤﻌﺎﻟﺠﺔ ووﻗﺖ اﻟﺘﻄﺒﯿﻖ، ﻻ ﯾﻤﻜﻦ اﻋﺘﺒﺎر ﻣﺮﻛﺐ اﻟﺮاﺗﻨﺞ ذاﺗﻲ اﻟﻠﺼﻖ ﻛﺘﻠﻲ اﻟﻤﻠﻲء ﺧﯿﺎرا أﻗﻞ ﺣﺴﺎﺳﯿﺔ<br/>ﻟﻠﺘﻘﻨﯿﺔ ﻋﻨﺪ ﻣﻘﺎرﻧﺘﮫ ﺑﺎﻟﻤﻮاد اﻟﺘﺮﻣﯿﻤﯿﺔ اﻟﺘﻘﻠﯿﺪﯾﺔ.<br/>اﻟﺘﻮﺻﯿﺎت اﻟﻌﻤﻠﯿﺔ:<br/>۱ .ﻟﺘﺄﻛﯿﺪ اﻟﻨﺘﺎﺋﺞ اﻟﺤﺎﻟﯿﺔ ، ﯾﻠﺰم إﺟﺮاء ﺗﺠﺎرب ﺳﺮﯾﺮﯾﺔ ذات أوﻗﺎت ﻣﺘﺎﺑﻌﺔ أطﻮل وأﺣﺠﺎم ﻋﯿﻨﺎت أﻛﺒﺮ.<br/>۲ .ﻟﺪﻋﻢ اﺳﺘﺨﺪام اﻟﻤﻮاد اﻟﺠﺪﯾﺪة ﻓﻲ اﻟﺘﻄﺒﯿﻘﺎت اﻟﻌﻼﺟﯿﺔ اﻟﻤﺘﻨﻮﻋﺔ ، ﯾﻮﺻﻰ ﺑﺈﺟﺮاء ﺗﺠﺎرب إﻛﻠﯿﻨﯿﻜﯿﺔ ﻟﺘﻘﯿﯿﻢ أداء أظﮭﺮ ﻣﺮﻛﺐ راﺗﻨﺞ<br/>ذاﺗﻲ اﻟﻠﺼﻖ ﻛﺘﻠﻲ اﻟﻤﻠﺊ.<br/>۳. ﯾﻤﻜﻦ اﺳﺘﺨﺪام ﻣﺮﻛﺐ اﻟﺮاﺗﻨﺞ ذاﺗﻲ اﻟﻠﺼﻖ ﻛﺘﻠﻲ اﻟﻤﻠﻲء ﻛﺒﺪﯾﻞ ﺳﺮﯾﺮي أﻗﻞ ﺣﺴﺎﺳﯿﺔ ﻟﻠﺘﻘﻨﯿﺔ ﻓﻲ اﻟﺘﺮﻣﯿﻤﺎت اﻟﻤﺘﻮﺳﻄﺔ ﻗﺼﯿﺮة اﻟﻤﺪى.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Oral Surgry
Source of heading or term qrmak
653 #0 - INDEX TERM--UNCONTROLLED
Uncontrolled term self- adhesive bulk-fill resin composite
-- bulk- fill resin composite
-- proximal lesions
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omaima Mohamed Safwat
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dina Mounir El kady
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2023
Supervisory body Omaima Mohamed Safwat
-- Dina Mounir El kady
Discussion body Olfat ElSayed Hassanein
-- Khalid Mohammed Noaman
Universities Cairo University
Faculties Faculty of Dentistry
Department Department of Restorative and Esthetic Dentistry
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
Reviser Names Huda
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 08.01.2025 90188 Cai01.09.03.Ph.D.2023.Mo.C 01010110090188000 08.01.2025 08.01.2025 Thesis