header

Assessment of wear of ot equator smart box attachment system in mandibular implant-retained overdenture with angulated implant versus straight angled implant : (Record no. 170958)

MARC details
000 -LEADER
fixed length control field 09273namaa22004331i 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - أخر تعامل مع التسجيلة
control field 20250223095524.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250223s2023 |||a|||f m||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.675
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 617.675
Edition number 21
097 ## - Degree
Degree M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.09.13.M.Sc.2023.Ab.A.
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Abdullah Mohamed Hassan Abdelghani,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Assessment of wear of ot equator smart box attachment system in mandibular implant-retained overdenture with angulated implant versus straight angled implant :
Remainder of title An-in vitro study /
Statement of responsibility, etc. By Abdullah Mohamed Hassan Abdelghani; Supervisors Prof. Dr. Nouran Abdel Nabi, Prof. Dr. Mohmed Farouk Abdulla, Dr. Mohamed Amr El Khashab.
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم تآكل نظام التعلق اوتي اكويتر سمرت بوكس في غرسة الفك السفلي المحتفظ بها بزاوية مقابل غرسات بزاوية مستقيمة :
Remainder of title دراسة معملية /
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2023.
300 ## - PHYSICAL DESCRIPTION
Extent 108 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.)-Cairo University, 2023.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 84-104.
520 ## - SUMMARY, ETC.
Summary, etc. Aim: To Compare change in deformation of the nylon cap between three different implant analog angulations of OT equator smart box attachment for a two implant-retained mandibular overdenture when subjected to cycles 75 000 and 150 000 of chewing cycles equivalent to 6 months and 12 months). Methodology: A completely edentulous mandibular stone model was pictured via digital camera photo extra-oral lab to produce a picture image J software. then file STL was used to virtually plan for two-implant analogs in the canine area bilaterally. Three groups were planned; In group I (straight); two implants analog were installed parallel to each other with a zero-degree difference in implant analog angulations, In group II (Buccal inclination) the left implant analog socket (A) was straight, and right implant analog socket (B) hole was installed with a 25degrees buccal angulation and group III ( Distally inclined) the left implant analog socket (A) straight and right implant analog socket (B) with a 25degrees distal angulation. Simulation of the oral mucosa was carried out by preparing a 2mm cutback on the residual alveolar ridge extending between the retromolar pads bilaterally. The overdenture was then designed and a space for the attachments housing of the three different angulations were designed to be added in the fitting surface of the overdenture to facilitate the pickup procedure. Nine models and nine overdentures were 3D-printed to be used in the present study. For all groups, the implants were installed in the prepared sockets by using self-cure acrylic resin, and then the smart box OT equator attachment was attached to the implant analogs and then picked up in the fitting surface of the denture. The geometric center was identified and then the initial wear (baseline values) was recorded for all groups using the universal testing machine. Then all groups were subjected to 75000 cycles and 150000 cycles using the chewing simulator and then the changes in the diameter of each nylon cap was carried out using the electron microscope, the values were recorded at base line (new cap) after 75,000 cycle and after 150,000 cycle. The mean change in diameter of the left implant (A), and right implant (B) for each group was then tabulated and statistically analyzed. Shapiro Wilk and Kolmogorov test was use for normality exploration. One Way ANOVA was used for multiple comparisons followed by Tukey`s Post Hoc test. Repetitive One-Way ANOVA for different intervals followed by Tukey`s Post Hoc test. Paired -t-test was used to measure changes in wear before and after the different cycles. The significant level (P-value) was determined to be significant as P-value > 0.05. Results: After being subjected to 75,000 cycles (equivalent to 6 month) there was a statically significant difference in the change in diameter of the left implant nylon cap (A) between the three groups. Group II showed the greatest change in diameter (1.86±0.33), followed by group I (1.49±1.09), while for group III there was a negative change in diameter (-0.17±0.45) (P=0.02).While for the right implant nylon cap (B) there was no statically significant difference in the change in diameter between the three groups ; Group I showed the greatest positive increase in diameter (1.30±1.15), followed by group III (0.04±0.21) while group III showed a negative change in diameter (-0.32±0.22) (P=0.06). There was no statistically significant difference in the change of the diameter between the three groups of the left implant nylon cap (A) after being subjected to 150,000 (equivalent to 12 month). Group II (2.23±0.30) showing the greatest positive change followed by group I (2.20±1.63), and group III showing the least change ( 0.01±0.26) (P=0.059). Similarly for the right implant nylon cap (B) there was no statistically significant difference in the change of the diameter between the three groups ;Group I showing the greatest positive change (0.95±0.65) , followed by Group III ( 0.09±0.68), and the least change in diameter was recorded by group II ( 0.03±0.44) (P=0.1). Conclusion: Smart box OT equator attachment showed the greatest significant deformation ( wear) with straight parallel implants after chewing cycles equivalent to 6- and 12 months. The Smart box OT equator with 25 degrees distally inclined implant showed the least deformation(wear) after chewing cycles equivalent to 6 months. While after chewing cycles equivalent to 12-month the 25-degree buccally inclined implants showed the least deformation (wear).
520 ## - SUMMARY, ETC.
Summary, etc. الهدف: مقارنة التغييرات في القدرة على الاحتمال بين ثلاث زوايا تناظرية مختلفة للزرع لمرفق الصندوق الذكي لخط الاستواء OT لاثنين من أسنان الفك السفلي الزائدة المحتفظ بها عند إخضاعها لدورات مضغ تبلغ 75000 و150000 ما يعادل 6 أشهر و12 شهرًا. المنهجية: تم أخذ صورة عن طريق كاميرا ميكروسكوب نموذج حجر الفك السفلي عديم الأسنان بالكامل باستخدام صورة ميكروسكوبية مختبري خارج الفم لإنتاج صورة عن طريق سوفت وير Image J تم بعد ذلك استخدام ملف STL للتخطيط فعليًا لنظيرين مزروعين في منطقة بشكل ثنائي. تم التخطيط لثلاث مجموعات. في المجموعة الأولى (مستقيم)؛ تم تركيب غرستين تناظريتين بالتوازي مع بعضهما البعض مع اختلاف درجة الصفر في الزوايا التناظرية للزرعة، في المجموعة الثانية (ميل الشدق) كان التجويف التناظري للغرسة اليسرى (A) مستقيمًا، وتم تركيب فتحة التناظرية للزرعة اليمنى (B) مع زاوية شدقية 25 درجة والمجموعة الثالثة (مائلة إلى أقصى الحدود) المقبس التناظري للزرعة اليسرى (أ) المقبس التناظري المستقيم والأيمن (ب) مع زاوية بعيدة 25 درجة. تم إجراء محاكاة للغشاء المخاطي للفم من خلال تحضير قطع بمقدار 2 مم على الحافة السنخية المتبقية الممتدة بين الوسادات خلف الرحى بشكل ثنائي. تم بعد ذلك تصميم طقم الأسنان الزائد وتم تصميم مساحة لمبيت الملحقات للزوايا الثلاثة المختلفة ليتم تضمينها في السطح الملائم لطقم الأسنان الزائد لتسهيل عملية الالتقاط. تمت طباعة تسعة نماذج وتسعة أطقم أسنان ثلاثية الأبعاد لاستخدامها في هذه الدراسة. بالنسبة لجميع المجموعات، تم تثبيت الغرسات في التجاويف المجهزة باستخدام راتنجات الأكريليك ذاتية المعالجة، ثم تم ربط ملحق خط الاستواء للصندوق الذكي OT بنظيرات الزرع ثم تم التقاطه في السطح المناسب للجهاز.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issued also as CD
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in English.
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Mineral composition
Source of heading or term qrmak
653 #0 - INDEX TERM--UNCONTROLLED
Uncontrolled term Smart box OT equator
-- distally
-- buccally
-- ANOVA
-- extra-oral
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nouran Abdel Nabi
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohmed Farouk Abdulla
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Amr El Khashab
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2023
Supervisory body Nouran Abdel Nabi
-- Mohmed Farouk Abdulla
-- Mohamed Amr El Khashab
Universities Cairo University
Faculties Faculty of Dentistry
Department Department of Implantology
905 ## - Cataloger and Reviser Names
Cataloger Name Sara Salah
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 23.02.2025 90646 Cai01.09.13.M.Sc.2023.Ab.A. 01010110090646000 23.02.2025 23.02.2025 Thesis