header

The effect of implant length and diameter on stress distribution of overdenture in kennedy class II cases : (Record no. 31319)

MARC details
000 -LEADER
fixed length control field 01871cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030255.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 100918s2009 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2009.As.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ashraf Ahmed Mohamed Saad
245 14 - TITLE STATEMENT
Title The effect of implant length and diameter on stress distribution of overdenture in kennedy class II cases :
Remainder of title Three-dimensional finite element analysis /
Statement of responsibility, etc. Ashraf Ahmed Mohamed Saad ; Supervised Ashraf Emil Eskander , Maha Wagdi , Sahar Ali Fawzy
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير طول و قطر الغرسة المعدنية على توزيع الضغوط في حالات التقسيم الثاني لكينيدي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ashraf Ahmed Mohamed Saad ,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent 127 Leaves :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. A finite element analysis study was carried out to evaluate the effect of implant length and diameter on stresses distribution around an implant used as distal support in kennedy class II implant supported partial overdenture. It was found that the stresses in the surrounding structures decrease with the increase of both the implant length and diameter. The implant diameter was found to be more effective factor
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Finite element analysis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Kennedy class II cases
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stresses
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ashraf Emil Eskander ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Wagdi Elkerdawy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sahar Ali Fawzy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Mustafa
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2009.As.E 01010110053757000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2009.As.E 01020110053757000 22.09.2023 CD - Rom 53757.CD