header

Accuracy of fit of implant- supported metal frameworks : (Record no. 32002)

MARC details
000 -LEADER
fixed length control field 01742cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030317.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 101106s2010 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2010.Di.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dina Magdi Hassan Elshehawi
245 10 - TITLE STATEMENT
Title Accuracy of fit of implant- supported metal frameworks :
Remainder of title An in vitro study /
Statement of responsibility, etc. Dina Magdi Hassen Elshehawi ; Supervised Hesham Katamish , Hanaa Ibraheem Sallam
246 15 - VARYING FORM OF TITLE
Title proper/short title دقة الهياكل المعدنية المثبته علي الغرسات السنيه :
Remainder of title دراسة معملية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Dina Magdi Hassan Elshehawi ,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent 131 Leaves :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The present investigation was designed to measure and compare (in vitro) the vertical marginal gap distance and precision of fit of implant- supported metal frameworks fabricated with and without waxing sleeves, before and after porcelain application. Results showed that before porcelain application, frameworks fabricated using waxing sleeves reported lower vertical marginal gap values (11.2 um) than those fabricated using conventional wax pattern technique 70 um
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fit
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Implant supported
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Metal frameworks
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hanaa Ibraheem Sallam ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hesham Katamish ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2010.Di.A 01010110054204000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2010.Di.A 01020110054204000 22.09.2023 CD - Rom 54204.CD