Xlpe cables insulation ageing due to electrical partial discharge / (Record no. 33939)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01602cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 110517s2011 ua a f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.13.07.Ph.D.2011.Ad.X |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Adel Ahmed Mohamed Elfarakoury |
245 10 - TITLE STATEMENT | |
Title | Xlpe cables insulation ageing due to electrical partial discharge / |
Statement of responsibility, etc. | Adel Ahmed Mohamed El Farakoury ; Supervised Osama Elsayed Gouda , Fatuhy Mohamed Tahoun |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقادم عزل كابلات البولي اثيلين متشابك الربط نتيجة للتفريغ الجزئي الكهربي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Adel Ahmed Mohamed Elfarakoury , |
Date of publication, distribution, etc. | 2011 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 145 P. : |
Other physical details | ill ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Electerical Power and Machines |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This thesis, used a new technology for on-site withstand test of power cable systems. It contains tests carried out the laboratory and on-site for HV cables having different lengths to determine the faulty joints and cable defects,and an over view covering best practices for cable systems installation and applying predictive diagnostic programs to aging cable systems |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cross-linked polyethylene |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | High voltage cable |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Partial discharge |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Fatuhy Mohamed Tahoun , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Osama Elsayed Gouda , |
Relator term | |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.13.07.Ph.D.2011.Ad.X | 01010110055262000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.13.07.Ph.D.2011.Ad.X | 01020110055262000 | 22.09.2023 | CD - Rom | 55262.CD |