header

Hybrid ventilation in office building in Egypt : (Record no. 36841)

MARC details
000 -LEADER
fixed length control field 01702cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030535.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120108s2011 ua dhb f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.02.M.Sc.2011.Sh.H
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Shaimaa Mohamed Reda Fayed
245 10 - TITLE STATEMENT
Title Hybrid ventilation in office building in Egypt :
Remainder of title Ventiilated double faÇade /
Statement of responsibility, etc. Shaimaa Mohamed Reda Fayed ; Supervised Mohamed Moemen Afify
246 15 - VARYING FORM OF TITLE
Title proper/short title التهوية المختلطة بالمبانى الادارية بمصر :
Remainder of title الواجهات الزجاجية ذات التهوية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Shaimaa Mohamed Reda Fayed ,
Date of publication, distribution, etc. 2011
300 ## - PHYSICAL DESCRIPTION
Extent 159 P. :
Other physical details charts , facsimiles , maps ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Architectural Engineering
520 ## - SUMMARY, ETC.
Summary, etc. Ventilation is the process of supplying fresh air to an enclosed space and removing contaminated air . Hybrid ventilation is designed to maintain acceptable indoor air quality that lies within comfort zone while preserving energy use building . As the critical element in any building is the faÇade where it interacts with the indoor and outdoor environment the ventilation double faÇade is surely an innovative method requiring technological development and support
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Comfort zone
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Hybrid ventilation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ventilation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Moemen Afify ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.02.M.Sc.2011.Sh.H 01010110056658000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.02.M.Sc.2011.Sh.H 01020110056658000 22.09.2023 CD - Rom 56658.CD