header

New MRI contrast agent using magnetized solutions / (Record no. 37805)

MARC details
000 -LEADER
fixed length control field 01706cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120311s2011 ua e f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.03.Ph.D.2011.Wa.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Wael AbouElwafa Ahmed Ali
245 10 - TITLE STATEMENT
Title New MRI contrast agent using magnetized solutions /
Statement of responsibility, etc. Wael AbouElwafa Ahmed Ali ; Supervised Yasser M. Kadah , Samir M. Badawi
246 15 - VARYING FORM OF TITLE
Title proper/short title صبغات للرنين المغناطيسى باستخدان المحاليل الممغنطه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Wael AbouElwafa Ahmed Ali ,
Date of publication, distribution, etc. 2011
300 ## - PHYSICAL DESCRIPTION
Extent 124 P. :
Other physical details plans ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Systems and Biomedical Engineering
520 ## - SUMMARY, ETC.
Summary, etc. This work and research is first time nationally and internationally introduced to be a novel research in healthy MRI contrast agents. A two water phantoms used. Each one is constructed of biodegradable latex rubber balloons filled with 450 ml. The resulted image for both magnetized and non-magnetized water phantoms are quantitatively processed by MATLAB Genetic Algorithms (Gas), These images show that T1 is increased to 1.513 s (225%) in magnetized phantom instead of 0.672 s in non magnetized one and S/N increased from 156.3 to 337.5-216%
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Magnetic resonance imaging
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Magnetized solutions
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term MRI agents
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Samir Mohamed Youssef Badawi ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yasser Mustafa Kadah ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.03.Ph.D.2011.Wa.N 01010110057374000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.03.Ph.D.2011.Wa.N 01020110057374000 22.09.2023 CD - Rom 57374.CD