MARC details
000 -LEADER |
fixed length control field |
01706cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
120311s2011 ua e f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.03.Ph.D.2011.Wa.N |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Wael AbouElwafa Ahmed Ali |
245 10 - TITLE STATEMENT |
Title |
New MRI contrast agent using magnetized solutions / |
Statement of responsibility, etc. |
Wael AbouElwafa Ahmed Ali ; Supervised Yasser M. Kadah , Samir M. Badawi |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
صبغات للرنين المغناطيسى باستخدان المحاليل الممغنطه |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Wael AbouElwafa Ahmed Ali , |
Date of publication, distribution, etc. |
2011 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
124 P. : |
Other physical details |
plans ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Systems and Biomedical Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This work and research is first time nationally and internationally introduced to be a novel research in healthy MRI contrast agents. A two water phantoms used. Each one is constructed of biodegradable latex rubber balloons filled with 450 ml. The resulted image for both magnetized and non-magnetized water phantoms are quantitatively processed by MATLAB Genetic Algorithms (Gas), These images show that T1 is increased to 1.513 s (225%) in magnetized phantom instead of 0.672 s in non magnetized one and S/N increased from 156.3 to 337.5-216% |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Magnetic resonance imaging |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Magnetized solutions |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
MRI agents |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Samir Mohamed Youssef Badawi , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Yasser Mustafa Kadah , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |