header

Precision of measurements from cone beam computed tomography and two different panoramic machines in pre - operative implant assessment / (Record no. 40442)

MARC details
000 -LEADER
fixed length control field 01921cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030721.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 121202s2012 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.Ph.D.2012.Wa.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Walid Samir Moukhtar Salem
245 10 - TITLE STATEMENT
Title Precision of measurements from cone beam computed tomography and two different panoramic machines in pre - operative implant assessment /
Statement of responsibility, etc. Walid Samir Moukhtar Salem ; Supervised Mushira M. Dahaba , Sherouk Hassan Ali Khalifa
246 15 - VARYING FORM OF TITLE
Title proper/short title دقة القياسات من الأشعة المقطعية بالحاسوب مخروطية الشعاع وجهازين تصوير بانورامى فى التقييم قبل الجراحى للغرس
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Walid Samir Moukhtar Salem ,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent 139P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral-Radiology
520 ## - SUMMARY, ETC.
Summary, etc. Preclude the accuracy of dimensional , linear and angular measurements yielded from CBCT images , panoramic images reformatted from spiral CT , panoramic images reformatted from CBCT and digital self - calibrated panoramic images in comparison to the measurements obtained from the cross - sectional CT . Twenty patients attending the Oral Maxillofacial Surgery Department , for placement of dental implants in both jaws (10 subjects required mandibular and the other ten required 10 maxillar)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cone - Beam CT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dental implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Spiral CT
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mushira M. Dahaba ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sherouk Hassan Ali Khalifa ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Fatma
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.Ph.D.2012.Wa.P 01010110058816000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.Ph.D.2012.Wa.P 01020110058816000 22.09.2023 CD - Rom 58816.CD