header

Computer vision techniques to compare accuracy of surgical guides in achieving implant parallism in edentulus mandible / (Record no. 41084)

MARC details
000 -LEADER
fixed length control field 01895cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030739.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 130115s2009 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2009.Al.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Aliaa Hamouda Abdaziz Elmahmoudy
245 10 - TITLE STATEMENT
Title Computer vision techniques to compare accuracy of surgical guides in achieving implant parallism in edentulus mandible /
Statement of responsibility, etc. Aliaa Hamouda Abdaziz Elmahmoudy ; Supervised Nadia Ahmed Abbas , Amal Mahmoud Ibrahim
246 15 - VARYING FORM OF TITLE
Title proper/short title استخدام وسائل الكمبيوتر المرئية لمقارنة دقة الدليل الجراحى فى تحقيق التوازى عند الغرس فى الفك السفلى بلا أسنان
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Aliaa Hamouda Abdaziz Elmahmoudy ,
Date of publication, distribution, etc. 2009
300 ## - PHYSICAL DESCRIPTION
Extent 74 Leaves :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to compare accuracy of different types of surgical guides to achieve parallelism between two implants placed between mental foramina in completely edentulous patients utilizing computer vision techniques . Results CAD/ CAM and base plate surgical guides were the most accurate followed by vaccum and clear acrylic surgical guides which showed less accuracy while the opposing arch surgcal guide proved t be the least accurate one
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Diagnostic guides
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dual purpose guide
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Positioning guides
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amal Mahmoud Ibrahim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nadia Ahmed Abbas ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2009.Al.C 01010110059282000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2009.Al.C 01020110059282000 22.09.2023 CD - Rom 59282.CD