Compressed sensing for better MRI image reconstruction / (Record no. 41127)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01818cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223030740.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 130116s2012 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.13.03.M.Sc.2012.Ab.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Abdulrahman Abdulaziz Mohamed Mohamed Sharaf |
245 10 - TITLE STATEMENT | |
Title | Compressed sensing for better MRI image reconstruction / |
Statement of responsibility, etc. | Abdulrahman Abdulaziz Sharaf ; Supervised Amr Abdurrahman Sharawi , Samir Mohamed Yusuf Badawy |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | استخدام الاحساس المنضغط لاعادة بناء أفضل لصور الرنين المغناطيسي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Abdulrahman Abdulaziz Mohamed Mohamed Sharaf , |
Date of publication, distribution, etc. | 2012 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 77 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Systems and Biomedical Engineering |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Partial fourier analysis is an old technique used to reconstruct the MRI image by acquiring only 50% of the image and estimate the other 50% by symmetry of the fourier domain. This thesis introduces the combination between the well-known partial fourier (Margosian and zero filling) algorithm and compressed sensing to determine the number of required fourier coefficients; we used their power distribution in the image for every case to show the efficiency and the quality of reconstructed MRI image |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Compressed sensing |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | MRI |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Partial fourier |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amr Abdurrahman Sharawi , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Samir Mohamed Yusuf Badawy , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.13.03.M.Sc.2012.Ab.C | 01010110059350000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.13.03.M.Sc.2012.Ab.C | 01020110059350000 | 22.09.2023 | CD - Rom | 59350.CD |