Evaluation of the accuracy of three dimensional printed mandibular models generated from cone beam computed tomography data / (Record no. 42131)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01794cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223030809.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 130320s2012 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.05.Ph.D.2012.No.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Noha Ossama Abdelaziz Issa |
245 10 - TITLE STATEMENT | |
Title | Evaluation of the accuracy of three dimensional printed mandibular models generated from cone beam computed tomography data / |
Statement of responsibility, etc. | Noha Ossama Abdelaziz Issa ; Supervised Nashwa Salah Mohamed , Hany Omar |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تقييم دقة نماذج الفك السفلي ثلاثية الأبعاد الناتجة من معطيات الأشعة المقطعية ذات الشعاع المخروطي |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Noha Ossama Abdelaziz Issa , |
Date of publication, distribution, etc. | 2012 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 112 Leaves : |
Other physical details | charts , photographs ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral-Radiology |
520 ## - SUMMARY, ETC. | |
Summary, etc. | To evaluate the dimensional accuracy of both, cone beam computed tomography and the three dimensional printed models which are generated from cone beam computed tomography data using a three dimensional printer. Ten dummy mandibular models simulating atrophic human bone were used in this study. Implants having length 16 mm were inserted after preparation in the dummy models in different sites |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cone beam computed tomography |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Dummy models |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Three dimensional printing |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hany Omar , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nashwa Salah Mohamed , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.05.Ph.D.2012.No.E | 01010110060025000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.05.Ph.D.2012.No.E | 01020110060025000 | 22.09.2023 | CD - Rom | 60025.CD |