header

Comparative evaluation of the internal adaptation of milled titanium and cast nickel- chromium single restorations / (Record no. 45326)

MARC details
000 -LEADER
fixed length control field 01860cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030940.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140311s2012 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2012.Sa.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Samira Atef Sayed
245 10 - TITLE STATEMENT
Title Comparative evaluation of the internal adaptation of milled titanium and cast nickel- chromium single restorations /
Statement of responsibility, etc. Samira Atef Sayed ; Supervised Jylan Fouad Elguindy , Hanan Naguib , Sahar Zaki
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسة مقارنة الاحكام الداخلى لتيجان التيتانيوم المخروط و سبائك النيكركروم المصنع بطريقة الصب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Samira Atef Sayed ,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent 93 Leaves :
Other physical details photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. Titanium is the most biocompatible metal used for dental casting; however, there is concern about its marginal accuracy in compare to the nickel- chrumium alloy. The purpose of this study was to evaluate and compare the marginal accuracy and internal fit of milled titanium and cast nickel- chromium single unit restorations. Milled titanium copings (n=20) and cast Ni=Cr copings (n=20) were fabricated with different axial taper (6, 10 degree) and finish line shoulder, chamfer
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Internal adaptation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Prosthodontics
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Titanium
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hanan Naguib ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Jylan Fouad Elguindy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sahar Zaki ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2012.Sa.C 01010110062130000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2012.Sa.C 01020110062130000 22.09.2023 CD - Rom 62130.CD