header

Setting up aQuality Assurance Program for Low Dose Rate (LDR) Remote Afterloading Brachytherapy Unit / (Record no. 45333)

MARC details
000 -LEADER
fixed length control field 031140000a22003370004500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030941.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 060917s2005 ua a f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title Eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.04.M.Sc.2005.Am.S.
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Amira Mostafa Zaki
245 10 - TITLE STATEMENT
Title Setting up aQuality Assurance Program for Low Dose Rate (LDR) Remote Afterloading Brachytherapy Unit /
Statement of responsibility, etc. Amira Mostafa Zaki ; Supervised ElSayed Awad Gaafar , Mohsen Samy Barsoom
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Amira Mostafa Zaki ,
Date of publication, distribution, etc. 2005
300 ## - PHYSICAL DESCRIPTION
Extent 80p :
Other physical details ill
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty Of Science - Department Of Biophysics
520 ## - SUMMARY, ETC.
Summary, etc. In brachytherapy , remote afterloading (RAL) devices present a technological advance that offers several advantages over the manual afterloading technique ; improved radiation protection to the medical staff , reduced possibility of human error , and the increased ease of achieving optimized dose distributionsThe reliance upon these devices to execute the prescribed treatment demands a comprehensive quality assurance programThe present work describes a quality assurance program that has been developed and implemented for a low dose rate remote afterloading brachytherapy facilityFor the treatment unit tests fall into mechanical and functional , autoradiographic , radiation safety and sources dosimetryAll the tests were successful in 962percent out of all checks appliedAdherence to the ALARA principle has reduced the radiation exposures for brachytherapy staff using our (RAL) device ; this is checked by radiation survey measurementsDosimetry measurements using a well type chamber and the RAL Cs 137 sources were done ; showing reproducibility for the well chamber 051 percentCalibration of single Cs 137 sources resulted in variation between measured and given source strength in the source report ranged from 19 percent to 24percentWhile for the treatment planning system manual calculations for a single source were done regularly to check the dose rate calculated by the computer planning system showing discrepancy less than 1percent between the manual and computerized calculations of the dose rateThe inverse - square distance factor was checked for calculating dose at different points resulting in 088percent difference between computerized and manual calculationsEvaluation for 15 patients ̀treatment plan , treated from cancer of cervix , was done showing a very consistent dose to the bladder and rectum (organs at risk) , dose to bladder ranged from 18 percent to 82percent , while for the rectum ranged from 45 percent to 85percent from the prescribed dose
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Brachytherapy
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dosimetry
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Low Dose Rate
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Quality Assurance
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name ElSayed Awad Gaafar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohsen Samy Barsoom ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Esam
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Mohamed
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.04.M.Sc.2005.Am.S. 01010110045289000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.04.M.Sc.2005.Am.S. 01020110045289000 22.09.2023 CD - Rom 45289.CD