Effect of cement thickness and cement type on stress distribution over implant retained cantilever fixed prosthesis / (Record no. 45359)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01732cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223030941.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 140312s2012 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2012.Mo.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mostafa Hassan Elkhazrajy |
245 10 - TITLE STATEMENT | |
Title | Effect of cement thickness and cement type on stress distribution over implant retained cantilever fixed prosthesis / |
Statement of responsibility, etc. | Mostafa Hassan Elkhazrajy ; Supervised Mohammed Labib Zamzam , Rasha Nabil Sami |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تاثير سمك ونوع الاسمنت على توزيع الضغط على الاستعاضات الصناعية الثابتة الملعقة على غرسات سنية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mostafa Hassan Elkhazrajy , |
Date of publication, distribution, etc. | 2012 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 104 Leaves : |
Other physical details | charts , facsimiles ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The aim od this study was to evaluate the effect of cement thickness and cement type on stress distribution over implants retaining cantilever fixed prosthesis. Forty five three units fixed partial dentures replacing the two maxillary premolars and first maxillary molar were fabricated where the maxillary first molar was the cantilever abutment |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cement retained |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Implant |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Stress distribution strain gauge |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohammed Labib Zamzam , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Rasha Nabil Sami , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Aml |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2012.Mo.E | 01010110062169000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2012.Mo.E | 01020110062169000 | 22.09.2023 | CD - Rom | 62169.CD |