header

Evaluation of the accuracy of implant placement using a surgical guide and a computer generated three dimensional printed model from cone beam coputed tomography data / (Record no. 46510)

MARC details
000 -LEADER
fixed length control field 01974cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031015.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140709s2013 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.11.Ph.D.2013.Am.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Amr Mohamed Ekram Ibrahim Hassan
245 10 - TITLE STATEMENT
Title Evaluation of the accuracy of implant placement using a surgical guide and a computer generated three dimensional printed model from cone beam coputed tomography data /
Statement of responsibility, etc. Amr Mohamed Ekram Ibrahim Hassan ; Supervised Khaled Mohamed Tawfik , Sameh Ahmed Seifeldeen
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم دقة وضع المغروس باستخدام دليل جراحى ونموذج ثلاثى الابعاد الناتج عن طريق الكمبيوتر باستخدام معطيات الاشعة المقطعية ذات الشعاع المخروطى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Amr Mohamed Ekram Ibrahim Hassan ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 139 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and dental Medicine - Department of Oral Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Objective: is to evaluate and compare the accuracy of implant placement after implantsurgery with a surgical guide constructed on a 3D printed model from cone beam comuted tomography data. methods: ten partially edentulous patients were selected for this study and were radiographed using cone beam computed tomography (CBCT). virtuarl implant planning was perormed on a three dimensional (3D) printed model using a 3D print
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dental implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Surgical guide
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Three dimensional printing
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Mohamed Tawfik ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sameh Ahmed Seifeldeen ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Aml
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.11.Ph.D.2013.Am.E 01010110062881000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.11.Ph.D.2013.Am.E 01020110062881000 22.09.2023 CD - Rom 62881.CD