header

Fracture resistance of two custom made and one prefabricated fiber posts at two different post lengths / (Record no. 47137)

MARC details
000 -LEADER
fixed length control field 01765cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140903s2013 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2013.Is.F
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Islam Munir Abdelrahman Ali
245 10 - TITLE STATEMENT
Title Fracture resistance of two custom made and one prefabricated fiber posts at two different post lengths /
Statement of responsibility, etc. Islam Munir Abdelrahman Ali ; Supervised Jylan .F. Elguindy , Nadia Zakaria Fahmy
246 15 - VARYING FORM OF TITLE
Title proper/short title مقاومه كسر نوعين من الدعامات الجذريه الليفيه المصنعه خصيصا و نوع من الدعامه الجذريه الليفيه الجاهزه بطولين مختليفين
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Islam Munir Abdelrahman Ali ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 98 Leaves :
Other physical details facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The aim of this study was to evaluate the fracture resistance of three different post materials two different post lengths. Materials: polythylene fiber posts, Ever stick fiber posts, Rely-x fiber posts. Methods: thirty sound mandibular premolars were collected. Each sample had their crown sectioned 2 mm coronal to the proximal Cement- Enamel junction, then were endodontically treated using rotary system (Bio-Race)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fracture resistance
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Polythylene fiber posts
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Rely-x fiber posts
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Jylan Fouad Elguindy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nadia Zakaria Fahmy ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Aml
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2013.Is.F 01010110063173000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2013.Is.F 01020110063173000 22.09.2023 CD - Rom 63173.CD