header

Corneal ablation profiles in lasik / (Record no. 48824)

MARC details
000 -LEADER
fixed length control field 02062cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 141220s2014 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.M.Sc.2014.Mo.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamad Badawy Rady Hassan
245 10 - TITLE STATEMENT
Title Corneal ablation profiles in lasik /
Statement of responsibility, etc. Mohamad Badawy Rady Hassan ; Supervised Mohamad Mahmoud Elsayaid , Hebatalla Abdelrahman Elgendy , Ahmed Abdelazim Abdelkader
246 15 - VARYING FORM OF TITLE
Title proper/short title الصور المختلفة لتذرية القرنية أثناء عملية الليزك
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamad Badawy Rady Hassan ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 141 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. Different ablation profiles are designed in attempts to achieve a perfect optical system. In a summary of types of ablation profiles in corneal laser surgery, treatments were divided into those based on the total optical system (the classic munnerlyn{u2019}s formula, wavefront-guided profiles, and wavefront - optimized profiles), and those based on the cornea (topography - guided profiles and aspheric / Q - factor - adjusted profiles). Some studies have compared different with variable results. Differences in inclusion criteria, study design, laser platforms, and surgeon variables may explain the varied results. In general, the change in postoperative HOAs after customized or optimized ablations is less than that for conventional, due to treatment of preexisting HOAs and / or less induction of new HOAs
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Aspheric / Q factor adjusted profiles
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Guided profiles
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Topography
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Abdelazim Abdelkader ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hebatalla Abdelrahman Elgendy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamad Mahmoud Elsayaid ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.M.Sc.2014.Mo.C 01010110064263000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.M.Sc.2014.Mo.C 01020110064263000 22.09.2023 CD - Rom 64263.CD