MARC details
000 -LEADER |
fixed length control field |
02322cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150104s2014 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.09.M.Sc.2014.Ah.C |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ahmed Mostafa Abdelsamad |
245 10 - TITLE STATEMENT |
Title |
Comparison between 3D rotational angiography and traditional fluroscopic guidance for arrhythmia mapping and ablation / |
Statement of responsibility, etc. |
Ahmed Mostafa Abdelsamad ; Supervised Ahmed Abdelaziz , Mohamed Magdy , Motaz Elhalag |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
المقارنة بين التصوير ثلاثى الأبعاد الدائرى و التصوير بأستخدام الأشعة الفلورية السينية كإرشاد فى تخطيط و كى مصدر إضطراب ضربات القلب |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ahmed Mostafa Abdelsamad , |
Date of publication, distribution, etc. |
2014 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
139 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Three dimensional rotational angiography (3DRA) is a promising new tool for 3D imaging strategy or combined with 3D electroanatomical mapping systems might add more understanding to cardiac anatomy in relation to the mapping and ablation procedures. The purpose of this prospective cohort study was to compare the procedural and clinical outcome of patients with all types of arrhythmia treated by catheter ablation using conventional fluoroscopy, three - dimensional (3D) electroanatomical mapping and/or 3DRA. From January 2013 to August 2013. Fifty consecutive patients with different types of arrhythmia (mean age 31.8 + 8.7 years old; 7 patients paroxysmal AF, 6 patients with VT,14 patients with WPW,21 patients with SVT, 2 patients with WCT were randomized to ablation using either 3DRA (18 patients), 3D electroanatomical mapping combined with 3DRA (13 patients) or standard fluoroscopy 19 patients |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
3D Rotational angiography |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Electroanatomical |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Fluroscopic guidance |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ahmed Abdelaziz , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Magdy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Motaz Elhalag , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |