MARC details
000 -LEADER |
fixed length control field |
01925cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150201s2014 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.25.Ph.D.2014.Ay.R |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ayman Mohamed Ahmed Zayan |
245 14 - TITLE STATEMENT |
Title |
The results of fixation of subtrochanteric fractures by locked plate biological and open method / |
Statement of responsibility, etc. |
Ayman Mohamed Ahmed Zayan ; Supervised Ahmed Galal , Ashraf Elnahal , Sherif Khaled |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
نتائج تثبيت كسر تحت المدورين بالشريحة ذاتية الغلق عن طريق التثبيت بيولوجيا و التثبيت المفتوح |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ayman Mohamed Ahmed Zayan , |
Date of publication, distribution, etc. |
2014 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
127 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Medicine Department of Orthopedic Surgery |
520 ## - SUMMARY, ETC. |
Summary, etc. |
According to our results, no superiority of either technique was demonstrated with respect to fracture union time and functional results. Except Submuscular biological plating had superiority regarding intraoperative blood loss and post-operative pain. From the overall results of this work and in comparing with other works which used different implants and post-operative function result PFLCP design is superior than DCS and condylar plat as it is easier method than both devices. Other bio statistical studies did not show regarding function result that proximal femoral nailing is superior to PFLCP |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Biological fixation |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Locked plate biological |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Subtrochanteric fractures |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ahmed Galal , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ashraf Elnahal , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Sherif Khaled , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Aml |
Reviser |
Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |