MARC details
000 -LEADER |
fixed length control field |
02552cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150321s2013 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.09.09.M.Sc.2013.Gh.M |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ghada Ahmed Abdelghaffar |
245 10 - TITLE STATEMENT |
Title |
Marginal adaptation of CAD - temp versus composite resin temporary crown / |
Statement of responsibility, etc. |
Ghada Ahmed Abdelghaffar ; Supervised Hesham Katamesh , Karl Hany Haliem |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
ا{uئإؤئ}{uئإ٩٨}{uئإأ٤}{uئإ٨إ}{uئإ٩١}{uئإؤ٦} ا{uئإؤئ}{uئإء٤}{uئإ٨إ}{uئإؤئ}{uئإؤ٤}{uئإئ٠} {uئإؤئ}{uئإإ٠}{uئإؤأ}{uئإ٨إ}د - {uئإ٩٧}{uئإإ٤}{uئإ٩٠} {uئإإ٣}{uئإؤ٨}{uئإ٨إ}{uئإ٩١}{uئإؤإ} ا{uئإؤئ}{uئإءإ}ا{uئإ٩٧}{uئإإ٨}{uئإ٩إ} ا{uئإؤئ}{uئإإ٤}{uئإءإ}{uئإؤآ}{uئإ٩٠} {uئإؤئ}{uئإإ٠}{uئإ٩٨}{uئإ٨إ}ج ا{uئإؤئ}{uئإإ٤}{uئإ٨٦}{uئإؤ٧}{uئإ٩٦} |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ghada Ahmed Abdelghaffar , |
Date of publication, distribution, etc. |
2013 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
65 Leaves : |
Other physical details |
facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontic |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study was designed to compare the marginal adaptation of CAD - temp material and composite resin crowns before and after cementation. For the purpose of standardization specially designed stainless steel die was constructed with the average dimention of the maxillary first premolar following the principles of tooth reduction for clinical abutment preparation, and having a finish line of 1 mm rounded shoulder, and with convergence angle 8 degrees. Duplication of the metal die was carried out using a low viscosity silicon duplicating material, then the duplicated impression will be poured into a reflactant stone to get a master stone die. In order to construct the CAD/CAM temporary crowns the stone die was scanned using the inEos scanner of the cerec inLab machine and the machine was selected a proper restoration design to be milled into an anatomical crown with the specific predetermined dimensions ,then we get the first groub of CAD - temp crowns ready to be tested |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
CAD - temp |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Marginal adaptation |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Resin temporary crown |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hesham Katamesh , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Karl Hany Haliem , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |