header

Evaluation of some mechanical properties of recently introduced thermoplastic denture base materials / (Record no. 50042)

MARC details
000 -LEADER
fixed length control field 01742cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031201.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150325s2013 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.10.M.Sc.2013.Mo.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mona Mahmoud Nour Eldin
245 10 - TITLE STATEMENT
Title Evaluation of some mechanical properties of recently introduced thermoplastic denture base materials /
Statement of responsibility, etc. Mona Mahmoud Nour Eldin ; Supervised Azza Abdelzaher Hashem , Dalia Ahmed Saba
246 15 - VARYING FORM OF TITLE
Title proper/short title بعض الخواص الميكانيكية لمواد اطقم اسنان حرارية حديثة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mona Mahmoud Nour Eldin ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 116Leaves :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc..) - Cairo University - Faculty of Oral and Dental Medicine - Department of Dental material
520 ## - SUMMARY, ETC.
Summary, etc. Purpose: The aim of this study was to evaluate flexural characteristics, impact strength and hardness of a Polyoxymethylene based (Bio dentaplast) and a polyamide based (Bre flex) thermoplastic denture base materials and to compare them with a conventional heat cured polymethyl methacrylate (Acrostone). Conclusion: Polyoxymethylene and Polyamide based thermoplastic denture base resins can be used as an alternative to conventional PMMA
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Denture base materials
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Recently introduced
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Thermoplastic
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Azza Abdelzaher Hashem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dalia Ahmed Saba ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.10.M.Sc.2013.Mo.E 01010110065005000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.10.M.Sc.2013.Mo.E 01020110065005000 22.09.2023 CD - Rom 65005.CD