100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Eyad Fathi saleem |
245 14 - TITLE STATEMENT |
Title |
The influence of core design on fracture resistance of all-ceramic crowns / |
Statement of responsibility, etc. |
Eyad Fathi saleem ; Supervised Eman Salah Hamdy , Jylan Fouad Elguindy |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تأثير تصميم اللب على مقاومة الكسر للتيجان الخزفية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Eyad Fathi saleem , |
Date of publication, distribution, etc. |
2011 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
75 Leaves : |
Other physical details |
charts , facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study was conducted to investigate the influence of core design on fracture resistance for all-ceramics crowns. a stainless-steel metal die was constructed then duplicated to produce stone dies for the construction of all-ceramic crowns, the die was designed to include 1.2mm shoulder finish line, and 60 total wall tapering, a total of fifteen posterior upper first premolar full crown restorations were divided into 3 groups (n=5) each: (1) Group I: core thickness 0.7mm (with 1mm collar all around), and veneer thickness 0.5mm, the core fabricated of all- ceramic zirconia-based crown and veneered with a ceramic (VITA VM®9, Vita zhanfabrik); and (2) Group II: core thickness 0.7mm ( all surface except buccal 0.5mm), and veneer thickness 0.5mm (all surface except buccal 0.7mm), with the same material of group I; and (3) Group III: core thickness 0.5mm (with 3mm palatal collar extended to contact area), and veneer thickness 0.7mm, with the same material of group I and II. Then metal die duplicated to epoxy resin material were used in fracture testing. Specimens were subjected to compressive loading using a universal testing machine at a crosshead speed of 1.0mm/min. A stereomicroscope was used to determined the failure modes of specimens |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Ceramic crowns |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Core design |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Fracture resistance |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Eman Salah Hamdy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Jylan Fouad Elguindy , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Soheir |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |