MARC details
000 -LEADER |
fixed length control field |
02575cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150506s2013 ua o f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.09.09.M.Sc.2013.Al.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ala{u2019}a Basel khafash |
245 10 - TITLE STATEMENT |
Title |
Evaluation of marginal accuracy, fracture resistance and mode of fracture of translucent zirconia bridges using machinable CAD / CAM technique / |
Statement of responsibility, etc. |
Ala{u2019}a Basel khafash ; Supervised Hesham Katamish , Ahmed Kamal Ebeid |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
تقييم الدقة الحافية و قوة و طريقة الكسر للجسور المصنوعة من الزركونيا الشفافة باستخدام الكاد / كام |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ala{u2019}a Basel khafash , |
Date of publication, distribution, etc. |
2013 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
98 Leaves : |
Other physical details |
photographs ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
The purpose of the present study was to investigate fracture resistance, marginal accuracy and mode of fracture of the CAD / CAM translucent zirconia three unit posterior bridges. The number of models used for this study were 20. All 20 models were constructed into a three unit FPD bridge with full coverage retainers on both abutments, restoring the maxillary second permanent premolar. The constructed 20 models, were divided prior to construction into two different groups, according to the material used in model construction. Each of the studied groups consisted of 10 models. The first group of FPDs was constructed using veneered zirconia cores. The second group of FPDs was constructed using Zirconia full anatomical bridge. The bridges were made using the cerec in Lab 3.88 CAD/CAM system, which is one of the best systems used in FPD construction owed to its highly accurate scanning, design and milling.Marginal accuracy, fracture resistance and mode of fracture were determined for the bridge models. Marginal accuracy was conducted using digital optical microscopy, while fracture resistance of the FPDs was tested using an electronic compressive strength measuring machine followed by SEM scanning to assess the effect of mode of fracture |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Fracture resistance |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Marginal accuracy |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Mode of fracture |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ahmed Kamal Ebeid , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hesham Katamish , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |