header

Revision of lumbar fixation : (Record no. 51003)

MARC details
000 -LEADER
fixed length control field 01933cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150523s2014 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.20.M.Sc.2014.Mo.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mostafa Fekry Ahmed Tantawy
245 10 - TITLE STATEMENT
Title Revision of lumbar fixation :
Remainder of title Causes and management /
Statement of responsibility, etc. Mostafa Fekry Ahmed Tantawy ; Supervised Mohamed Shehab Saad Zaghloul , Wael Mohamed Nazim , Ahmed Salah Kamel
246 15 - VARYING FORM OF TITLE
Title proper/short title مراجعة تثبيت الفقرات القطنية جراحيا :
Remainder of title الأسباب و العلاج
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mostafa Fekry Ahmed Tantawy ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 111 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Neurosurgery
520 ## - SUMMARY, ETC.
Summary, etc. Revision of lumbar fixation is now a major challenging issue in neurological surgery practice and used in different clinical settings such as adjacent segment failure, maldirected or broken screws. The reasons for failure are many and varied. Broken screws, spinal stenosis, pseudarthrosis and spinal instability top the list of causes. Patients who were helped the most by revision surgery had spinal stenosis or else instability in the lumbar segment above or below the previous fusion. Surgical treatment options are removal of the screws whether maldirected or broken and fixation by instrumentation or not according to the stability, or extension of instrumentation in case of adjacent segment failure
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Broken screw
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fusion
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pseudarthrosis
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Salah Kamel ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Shehab Saad Zaghloul ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wael Mohamed Nazim ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.20.M.Sc.2014.Mo.R 01010110065651000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.20.M.Sc.2014.Mo.R 01020110065651000 22.09.2023 CD - Rom 65651.CD