MARC details
000 -LEADER |
fixed length control field |
02607cam a2200313 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
150525s2013 ua o f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.09.02.M.Sc.2013.Ma.E |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mahmoud Mohamed Abdulbaky |
245 10 - TITLE STATEMENT |
Title |
Evaluation of the efficacy of reciproc and revo - s in preparation of oval root canals using cone beam computed tomography / |
Statement of responsibility, etc. |
Mahmoud Mohamed Abdulbaky ; Supervised Hebatallah Mohamed Maged Elfar , Hani Samy Sadek |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
فى تحضير قنوات الجذور البيضاوى باستخدام جهاز الأشعة المخروطى receiproc revo - s تقييم فعالية انظمة النيكل تايتانيوم من نوع |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mahmoud Mohamed Abdulbaky , |
Date of publication, distribution, etc. |
2013 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
106 Leaves : |
Other physical details |
photographs ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
To evaluate the efficacy of revo - S and reciproc R40 NiTi files in preparation of oval root canals using cone beam computed Tomography (CBCT). Forty extracted single rooted premolars were divided into 2 groups (n = 20). Group 1 (R - S) were prepared with revo - S up to size #40 / .06. Group 2 (R40) were prepared to the same size with a single file R40. Pre - and post-instrumentation CBCT scanning was done. Calculated parameters were: increase ({u1EB0}) in canal volume and surface area. Transportation, centering ability, and untouched canal areas were tested at 3, 6, 9 mms axial sections. Statistical analyses were made using Mann-Whitney U and Friedman{u2019}s test (P {u2264} 0.05). Significant increase in {u1EB0} volume (P = .000 and P = .003 for R - S and R40 respectively) and {uF044} surface area (P = 0.048 and P = 0.038 for R - S and R40 respectively) was found for both instrumentation kinematics with no significant differences between them. Canals{u2019} transportation and decreased centering ratio were detected in both groups at all tested levels with insignificant smaller values in the M - D direction. Exception was found at 9mm level where a significantly highest transportation was found in R - S group P = 0.022 |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Computed tomography |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Instrumentation kinematics |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Oval root canals |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hani Samy Sadek , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hebatallah Mohamed Maged Elfar , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |