MARC details
000 -LEADER |
fixed length control field |
02565cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
151012s2014 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.24.M.Sc.2014.So.I |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Soheir Hozayen Gaballa |
245 10 - TITLE STATEMENT |
Title |
IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract / |
Statement of responsibility, etc. |
Soheir Hozayen Gaballa ; Supervised Karim Adly Raafat , Nahla Borhan Abohussein , Riham Samy Hanafy Mahmoud Allam |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
مقارنة بين استخدام مقياس العدسة الضوئى ومقياس العدسة الفوق صوتى فى حساب قوة العدسة الداخلية للعين فى أنواع مختلفة من المياة البيضاء |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Soheir Hozayen Gaballa , |
Date of publication, distribution, etc. |
2014 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
71P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study discusses the IOL power calculation and hence the post operative refractive error through comparison between the use of IOL master and A- scan biometry in measuring the axial length of the eye. This comparison has been done in myopic eyes, silicone filled eyes, and eyes with nuclear cataract grade I&II. This study concluded that The IOL Master has simplified considerably the process of ocular biometry. It is a non-contact technique, which does not require use of topical anesthesia, thus providing comfort to the patient and preventing corneal abrasions and the transmission of infections. Furthermore it has greater accuracy than ultrasound biometry because it measures the ocular AXL along the visual axis, as the patient fixates at the measurement beam, whereas during ultrasound biometry a misalignment between the measured axis and the visual axis may result in erroneously longer AXL measurements. This is especially important in eyes with posterior pole staphyloma because of the more precise localization of the fovea. In addition it is easier to master its use |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Cataract |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
IOL Master Optical Biometry |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Ultrasound biometry |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Karim Adly Raafat , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Nahla Borhan Abohussein , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Riham Samy Hanafy Mahmoud Allam , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Soheir |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |