header

IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract / (Record no. 52721)

MARC details
000 -LEADER
fixed length control field 02565cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151012s2014 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.M.Sc.2014.So.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Soheir Hozayen Gaballa
245 10 - TITLE STATEMENT
Title IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract /
Statement of responsibility, etc. Soheir Hozayen Gaballa ; Supervised Karim Adly Raafat , Nahla Borhan Abohussein , Riham Samy Hanafy Mahmoud Allam
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة بين استخدام مقياس العدسة الضوئى ومقياس العدسة الفوق صوتى فى حساب قوة العدسة الداخلية للعين فى أنواع مختلفة من المياة البيضاء
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Soheir Hozayen Gaballa ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 71P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. This study discusses the IOL power calculation and hence the post operative refractive error through comparison between the use of IOL master and A- scan biometry in measuring the axial length of the eye. This comparison has been done in myopic eyes, silicone filled eyes, and eyes with nuclear cataract grade I&II. This study concluded that The IOL Master has simplified considerably the process of ocular biometry. It is a non-contact technique, which does not require use of topical anesthesia, thus providing comfort to the patient and preventing corneal abrasions and the transmission of infections. Furthermore it has greater accuracy than ultrasound biometry because it measures the ocular AXL along the visual axis, as the patient fixates at the measurement beam, whereas during ultrasound biometry a misalignment between the measured axis and the visual axis may result in erroneously longer AXL measurements. This is especially important in eyes with posterior pole staphyloma because of the more precise localization of the fovea. In addition it is easier to master its use
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cataract
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term IOL Master Optical Biometry
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ultrasound biometry
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Karim Adly Raafat ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nahla Borhan Abohussein ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Riham Samy Hanafy Mahmoud Allam ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.M.Sc.2014.So.I 01010110066480000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.M.Sc.2014.So.I 01020110066480000 22.09.2023 CD - Rom 66480.CD