MARC details
000 -LEADER |
fixed length control field |
02302cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
151013s2015 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.15.M.Sc.2015.Mo.T |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mohamed Mahmoud Hussein |
245 10 - TITLE STATEMENT |
Title |
Transvaginal utrasonographic assessment of lower uterine segment thickness and prediction of uterine rupture in cases of vaginal birth after caesarean delivery / |
Statement of responsibility, etc. |
Mohamed Mahmoud Hussein ; Supervised Mohamed Ali Abdelkader , Abdallah Yehia Elkateb , Yahia Mohamed Elfaissal |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
استخدام الموجات فوق الصوتية المهبلية فى تقييم سمك الجزء السفلى من الرحم بحدوث انفجار رحمى فى حالات الولادة المهبلية بعد قيصرية سابقة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mohamed Mahmoud Hussein , |
Date of publication, distribution, etc. |
2015 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
84 P. : |
Other physical details |
charts , facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Objective:to assess the strength of the association between transvaginal ultrasonographic measurement of the lower uterine segment in women with prior one CS undergoing a trial of vaginal birth and uterine scar defect at delivery and to ascertain the best cut-off value for predicting uterine rupture . Results: Uterine dehiscence was found in 3 cases (5%).There were no cases ofuterine rupture. The thicknessof lower uterine segment among the gravidas with dehiscence was significantly less than those without dehiscence. The cut-off value for the thickness of lower uterine segment was 3.0 mm as calculated by the receiver operating characteristic curve .The sensitivity was 89.5% , specificity 75.6% , positive predictive value 63% ,negative predictive value 90.3%. |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Lower uterine segment and VBAC |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Uterine dehiscence |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Uterine rupture |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Abdallah Yehia Elkateb , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Ali Abdelkader , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Yahia Mohamed Elfaissal , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Soheir |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |