header

Dual force magnitudes on implant supported canine retraction / (Record no. 53057)

MARC details
000 -LEADER
fixed length control field 02082cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031329.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151102s2013 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.06.M.Sc.2013.Sh.D
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Sharif Mohammed Bushnaq
245 10 - TITLE STATEMENT
Title Dual force magnitudes on implant supported canine retraction /
Statement of responsibility, etc. Sharif Mohammed Bushnaq ; Supervised Amr Abdelrehim Hussein Labib , Dalia Elboghdady
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير مقدار قوتين على معدل سحب الناب المدعوم بغرس مجهرى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Sharif Mohammed Bushnaq ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 100 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The aim of this clinical study was to compare the use of two different force magnitudes (100 gm and 200 gm) with indirect mini-screw implant anchorage, and evaluating the rate of canine movement, amount of molar anchorage loss, canine disto-buccal rotation and canine mesio-distal tipping. Results: The amount of initial tooth movement (T0-T1) was not related to force magnitude. However, during (T1-T2) and (T2-T3) periods, significant increase in the amount and rate of tooth movement were found with 200 gm group than 100 gm group. Canine rotation, tipping and anchorage loss were significantly higher in 200 gm group than 100 gm group. Conclusion: Canine retraction proceeds at a faster rate in 200 gm group. Indirect mini-screw anchorage was not effective in preventing anchorage loss in both groups.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Force magnitude
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mini- screw
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Rate of canine retraction
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Abdelrehim Hussein Labib ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dalia Elboghdady ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.06.M.Sc.2013.Sh.D 01010110066661000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.06.M.Sc.2013.Sh.D 01020110066661000 22.09.2023 CD - Rom 66661.CD