header

An assessment of pretreatment performance and process design of reverse osmosis plant : (Record no. 53398)

MARC details
000 -LEADER
fixed length control field 02377cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031338.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151119s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.05.M.Sc.2015.Ne.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nermeen Ahmed Abdelbaery Elmeleegae
245 13 - TITLE STATEMENT
Title An assessment of pretreatment performance and process design of reverse osmosis plant :
Remainder of title cases study /
Statement of responsibility, etc. Nermeen Ahmed Abdelbaery Elmeleegae ; Supervised Ehab M. Rashed , Khaled Z. Abdalla
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم كفاءة نظم المعالجة الأولية و التصميم لمحطات التحلية بتقنية الأسموزية العكسية :
Remainder of title دراسة حالة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nermeen Ahmed Abdelbaery Elmeleegae ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 177 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering
520 ## - SUMMARY, ETC.
Summary, etc. Membrane fouling is the main operating problem of reverse osmosis process, the research investigate the influences of fouling materials on the performance of three plant fed by (fresh municipal water, seawater, and ground water) assess the pretreatment processes, and normalizes and optimizes reverse osmosis unit design, the research conclude that, in first plant, aluminum-based fouling increases the permeate salinity 3 times, decrease flux 25% in 3 months in municipal water plant, replacing conventional pretreatment by ultrafiltration membrane pretreatment restore the plant performance. In second plant, colloidal and organic fouling decreases the fouling factor that elevates the applied pressure 15% in seawater plant. In third plant, iron-organic fouling, increase of well salinity and temperature, and improper pretreatment and membrane type causes 7 times replacement of plant membranes and prolong shutdown intervals, by changing these constrains the plant performance is modified
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fouling
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pretreatment
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Reverse Osmosis Membrane
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ehab Mohamed Rashed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Zaher Abdalla,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.05.M.Sc.2015.Ne.A 01010110066744000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.05.M.Sc.2015.Ne.A 01020110066744000 22.09.2023 CD - Rom 66744.CD