MARC details
000 -LEADER |
fixed length control field |
02316cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
151125s2015 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.11.M.Sc.2015.Re.N |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Redhwan Nasser Ali Algabri |
245 10 - TITLE STATEMENT |
Title |
Numerical investigation of flow patterns and thermal comfort in an air-conditioned mosque / |
Statement of responsibility, etc. |
Redhwan Nasser Ali Algabri ; Supervised Essam E. Khalil , Mahmoud A. Fouad , Esmail Mohamed Elbialy |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
دراسة عددية لأنماط السريان و الراحة الحرارية داخل مسجد مكيف الهواء |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Redhwan Nasser Ali Algabri , |
Date of publication, distribution, etc. |
2015 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
127 P. : |
Other physical details |
charts , photographs ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
The air conditioning applications in mosques are considered as one of the important HVAC applications, which prayers comfort depend on the behavior of the airflow, the distributions of temperatures and relative humidity and concentration of carbon dioxide due to high occupancy load of prayers. So, the present thesis is devoted to numerically investigate the influence of location and number of persons on airflow properties in mosque. The work focuses on airflow patterns, thermal behaviour and carbon dioxide dispersion in mosque where large number of prayers standing. The effectiveness of an airflow system is commonly assessed by the successful removal of sensible and latent loads from occupants with additional of attaining air pollutant at a prescribed level to attain the human thermal comfort conditions and to improve the indoor air quality. Commercially packaged floor mounted air conditioning unit is a typical unit for such applications, due to the advantages it possesses over other types of HVAC systems and units |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
CFD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Flow patterns |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Thermal comfort |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Esmail Mohamed Elbialy , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Essam Edin Khalil , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mahmoud Ahmed Fouad , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |