Influence of microcurrent electrical stimulation on blood flow in normal subjects / (Record no. 53724)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02839cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031347.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 151205s2015 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.21.09.M.Sc.2015.Na.I |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Nagwa Sayed Abdelwahed Hasan |
245 10 - TITLE STATEMENT | |
Title | Influence of microcurrent electrical stimulation on blood flow in normal subjects / |
Statement of responsibility, etc. | Nagwa Sayed Abdelwahed Hasan ; Supervised Kadria Hosny Mohamed , Marzouk Abdelfattah Ellethy |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تأثيرالتنبية بالتيارالكهربائى المتناهى فى الصغر على تدفق الدم لدى الأشخاص الطبيعيين |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Nagwa Sayed Abdelwahed Hasan , |
Date of publication, distribution, etc. | 2015 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 88 P. : |
Other physical details | charts . facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Blood flow is an important factor which can affect the repair and healing of injured tissues. There are many factors that may affect the blood flow. Electrical stimulation has been showed to produce long term changes in vascularization at the capillary level. This study was done to investigate the influence of microcurrent electrical stimulation (MES) on blood flow in normal subjects. Thirty healthy participants with mean age (28.77 ± 3.501) years, and the mean value of their body mass index was (23.20 ± 1.332) kg/m. Participants were assigned randomly into two equal groups; group (A) received high frequency MES with 125 Hz frequency for 30 min. while, group (B) received low MES with frequency 40 Hz for 30 min. All participants in both groups were assessed for resistivity Index, Total blood flow volume, mean blood flow velocity and peak systolic velocity by using ultrasonic doppler before and immediately after microcurrent application. Microcurrent electrical stimulation showed statistical significant improvement in blood flow resistivity index, total blood flow volume, mean blood flow velocity and peak systolic velocity in posterior tibial artery of normal healthy subjects, with significant statistical difference by using high frequency versus low frequency. The study revealed that both high frequency and low frequency microcurrent electrical stimulation were effective for improving the blood flow on the posterior tibial artery in normal healthy subjects |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Blood flow |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Microcurrent electrical stimulation |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Resistivity index |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Kadria Hosny Mohamed , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Marzouk Abdelfattah Ellethy , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.21.09.M.Sc.2015.Na.I | 01010110066992000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.21.09.M.Sc.2015.Na.I | 01020110066992000 | 22.09.2023 | CD - Rom | 66992.CD |