header

Influence of microcurrent electrical stimulation on blood flow in normal subjects / (Record no. 53724)

MARC details
000 -LEADER
fixed length control field 02839cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031347.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151205s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.09.M.Sc.2015.Na.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nagwa Sayed Abdelwahed Hasan
245 10 - TITLE STATEMENT
Title Influence of microcurrent electrical stimulation on blood flow in normal subjects /
Statement of responsibility, etc. Nagwa Sayed Abdelwahed Hasan ; Supervised Kadria Hosny Mohamed , Marzouk Abdelfattah Ellethy
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثيرالتنبية بالتيارالكهربائى المتناهى فى الصغر على تدفق الدم لدى الأشخاص الطبيعيين
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nagwa Sayed Abdelwahed Hasan ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 88 P. :
Other physical details charts . facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science
520 ## - SUMMARY, ETC.
Summary, etc. Blood flow is an important factor which can affect the repair and healing of injured tissues. There are many factors that may affect the blood flow. Electrical stimulation has been showed to produce long term changes in vascularization at the capillary level. This study was done to investigate the influence of microcurrent electrical stimulation (MES) on blood flow in normal subjects. Thirty healthy participants with mean age (28.77 ± 3.501) years, and the mean value of their body mass index was (23.20 ± 1.332) kg/m. Participants were assigned randomly into two equal groups; group (A) received high frequency MES with 125 Hz frequency for 30 min. while, group (B) received low MES with frequency 40 Hz for 30 min. All participants in both groups were assessed for resistivity Index, Total blood flow volume, mean blood flow velocity and peak systolic velocity by using ultrasonic doppler before and immediately after microcurrent application. Microcurrent electrical stimulation showed statistical significant improvement in blood flow resistivity index, total blood flow volume, mean blood flow velocity and peak systolic velocity in posterior tibial artery of normal healthy subjects, with significant statistical difference by using high frequency versus low frequency. The study revealed that both high frequency and low frequency microcurrent electrical stimulation were effective for improving the blood flow on the posterior tibial artery in normal healthy subjects
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Blood flow
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Microcurrent electrical stimulation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Resistivity index
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Kadria Hosny Mohamed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Marzouk Abdelfattah Ellethy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.09.M.Sc.2015.Na.I 01010110066992000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.09.M.Sc.2015.Na.I 01020110066992000 22.09.2023 CD - Rom 66992.CD