header

Short stem femoral component in primary hip arthroplasty / (Record no. 53995)

MARC details
000 -LEADER
fixed length control field 02149cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031355.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151219s2015 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.25.Ph.D.2015.Ad.S
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Adel Sayed Abdelghani
245 10 - TITLE STATEMENT
Title Short stem femoral component in primary hip arthroplasty /
Statement of responsibility, etc. Adel Sayed Abdelghani ; Supervised Tarek Abdelshafy , Abdelsalam Abdelghaffar , Ahmad Morrah
246 15 - VARYING FORM OF TITLE
Title proper/short title إستخدام جذع المفصل القصير فى عملية استبدال مفاصل الحوض الاولية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Adel Sayed Abdelghani ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 222 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopedic Surgery
520 ## - SUMMARY, ETC.
Summary, etc. Redistribution of bone mass from the proximal to more distal zones reported in conventional stems reflecting distal load transfer to diaphyseal area. While increased bone density was observed in the proximal periprosthetic area in the short stem design. Factors affecting bone remodeling after THA, include patient-related factors such as sex, age, underlying disease and quality of bone before the hip replacement, and also implant-related factors such as size, stiffness, surface finish and postoperative implant stability short stem hip arthroplasty is a reliable procedure resulting in excellent implant fixation and a predictable clinical outcome in the short term. This study have shown low rates of mechanical failure in a series of relatively young and active patients, but long - term outcome assessments are required to determine whether this type of fixation will stand the test of time
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term BMD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term DEXA
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term THA
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abdelsalam Abdelghaffar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmad Morrah ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Tarek Abdelshafy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.25.Ph.D.2015.Ad.S 01010110067228000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.25.Ph.D.2015.Ad.S 01020110067228000 22.09.2023 CD - Rom 67228.CD