MARC details
000 -LEADER |
fixed length control field |
02558cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
160308s2015 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.11.24.Ph.D.2015.Ah.C |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ahmed Mohamed Elshewy |
245 12 - TITLE STATEMENT |
Title |
A comparative study between standard and transepithelial corneal collagen crosslinking in keratoconus / |
Statement of responsibility, etc. |
Ahmed Mohamed Elshewy ; Supervised Riad Bahey Eldin Shalash , Hazem Mohamed Yassin , Mohamed Ahmed Awadalla |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
دراسه مقارنه بين تشابك الكولاجين للقرنيه التقليدى و عبر الخلايا الطلائيه فى القرنيه المخروطيه |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Ahmed Mohamed Elshewy , |
Date of publication, distribution, etc. |
2015 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
117 P. : |
Other physical details |
facsimiles ; |
Dimensions |
25cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Ophthalmology |
520 ## - SUMMARY, ETC. |
Summary, etc. |
To compare safety and efficacy of transepithelial (epi - on) corneal collagen crosslinking as opposed to standard (epi-off) corneal collagen crosslinking, in the management of keratoconus. Prospective, interventional, non-randomized, non controlled study. 40 keratoconus eyes divided in 2 groups: 20 eyes in Group (1) received standard (epi - off) crosslinking and 20 eyes in Group 2 received transepithelial (epi - on) crosslinking. All patients were evaluated regarding best spectacle corrected visual acuity (BSCVA), corneal maximum keratometric value (Kmax), central corneal thickness (CCT), corneal hysteresis (CH) and corneal resistance factor (CRF). These aspects were evaluated preoperatively and postoperatively after 3, 6 and 12 months. Regarding BSCVA, standard CXL group showed insignificantly increase (improvement) after 1 year, while Transepithelial CXL group showed significantly decrease (worsening). Regarding Kmax, both groups showed flattening, which was statistically significant in Standard CXL group and insignificant in Transepithelial CXL group. Regarding CCT, both groups showed statistically significant thinning. Regarding CH and CRF, there was decrease in values in both groups |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Corneal collagen crosslinking |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Keratoconus |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Transepithelial |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Hazem Mohamed Yassin , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Mohamed Ahmed Awadalla , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Riad Bahey Eldin Shalash , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Samia |
Reviser |
Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |