header

Numerical investigatios for natural ventilation techniques in mosques / (Record no. 55462)

MARC details
000 -LEADER
fixed length control field 02011cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160310s2015 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2015.Mo.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Ahmed Ibrahim Aldosoqy
245 10 - TITLE STATEMENT
Title Numerical investigatios for natural ventilation techniques in mosques /
Statement of responsibility, etc. Mohamed Ahmed Ibrahim AlDosoqy ; Supervised Essam E. Khalil Hassan Khalil , Samy Morad Morcos , Gamal Elhariry
246 15 - VARYING FORM OF TITLE
Title proper/short title دراسات عددية عن التهوية الطبيعية في المساجد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Ahmed Ibrahim Aldosoqy ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 125 P. :
Other physical details facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. This research presents a numerical study for natural ventilation techniques in mosques and worships. This research investigates the effect of using wind towers (wind catchers) in small, passive cooling and air distribution by wind catcher and its technique . Also, the effect of open windows and close windows on the air distribution in mosque. Minimum wind speed, maximum outdoor temperature and maximum allowable relative humidity to allow the natural ventilation process are determined to providing the thermal comfort zone inside the mosque space. Fluent 14 (CFD) software version 14.0 is utilized to simulate mosques models. Results show that adding of wind towers to the conditioned space improve the thermal comfort sensation for prayers
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Green Technology
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Natural Ventilation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Thermodynamic Simulation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam E. Khalil Hassan Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Gamal Elhariry ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Samy Morad Morcos ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Aml
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2015.Mo.N 01010110068106000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2015.Mo.N 01020110068106000 22.09.2023 CD - Rom 68106.CD