MARC details
000 -LEADER |
fixed length control field |
02011cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
EG-GiCUC |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
160310s2015 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EG-GiCUC |
Language of cataloging |
eng |
Transcribing agency |
EG-GiCUC |
041 0# - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
049 ## - LOCAL HOLDINGS (OCLC) |
Holding library |
Deposite |
097 ## - Thesis Degree |
Thesis Level |
M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
Classification number |
Cai01.13.11.M.Sc.2015.Mo.N |
100 0# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Mohamed Ahmed Ibrahim Aldosoqy |
245 10 - TITLE STATEMENT |
Title |
Numerical investigatios for natural ventilation techniques in mosques / |
Statement of responsibility, etc. |
Mohamed Ahmed Ibrahim AlDosoqy ; Supervised Essam E. Khalil Hassan Khalil , Samy Morad Morcos , Gamal Elhariry |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
دراسات عددية عن التهوية الطبيعية في المساجد |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Cairo : |
Name of publisher, distributor, etc. |
Mohamed Ahmed Ibrahim Aldosoqy , |
Date of publication, distribution, etc. |
2015 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
125 P. : |
Other physical details |
facsimiles ; |
Dimensions |
30cm |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This research presents a numerical study for natural ventilation techniques in mosques and worships. This research investigates the effect of using wind towers (wind catchers) in small, passive cooling and air distribution by wind catcher and its technique . Also, the effect of open windows and close windows on the air distribution in mosque. Minimum wind speed, maximum outdoor temperature and maximum allowable relative humidity to allow the natural ventilation process are determined to providing the thermal comfort zone inside the mosque space. Fluent 14 (CFD) software version 14.0 is utilized to simulate mosques models. Results show that adding of wind towers to the conditioned space improve the thermal comfort sensation for prayers |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE |
Additional physical form available note |
Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Green Technology |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Natural Ventilation |
653 #4 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Thermodynamic Simulation |
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Essam E. Khalil Hassan Khalil , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Gamal Elhariry , |
Relator term |
|
700 0# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Samy Morad Morcos , |
Relator term |
|
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Aml |
Reviser |
Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
Cataloger |
Nazla |
Reviser |
Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Thesis |