header

Role of pulse oximetry in early detection of critical congenital heart diseases / (Record no. 55573)

MARC details
000 -LEADER
fixed length control field 02458cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160316s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.28.M.Sc.2015.Di.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Dina Salah Eldin Hannoura
245 10 - TITLE STATEMENT
Title Role of pulse oximetry in early detection of critical congenital heart diseases /
Statement of responsibility, etc. Dina Salah Eldin Hannoura ; Supervised Iman Fathy Iskander , Wael Attia , Salma Elhouchi
246 15 - VARYING FORM OF TITLE
Title proper/short title فاعلية مقياس تأكسج الدم فى التشخيص المبكر لأمراض القلب الخلقية الحرجة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Dina Salah Eldin Hannoura ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 98 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics
520 ## - SUMMARY, ETC.
Summary, etc. Although many cardiac lesions are diagnosed antenatally by fetal echocardiography, fatal critical congenital heart defects may still be missed. The purpose of this study is to evaluate the capability of pulse oximetry screening for early detection of critical congenital cardiovascular malformations in asymptomatic newborns. Pulse oximetry screening was performed on 118 asymptomatic newborns in the well infant nursery. Echocardiography examination was performed on all of the newborns included in the study. Data regarding true and false positives as well as negatives were collected and analyzed. With an oxygen saturation cut off of 94% pulse oximetry screening helped to diagnose 8 cases with critical congenital heart diseases while it failed to diagnose a case of Fallot tetralogy and another one with severe valvular pulmonary stenosis. This study revealed that best cut off value for preductal O2 saturation in relation to echocardiographic finding was 94% with standard error = 0.058 and 95% confidence interval = 0.718 - 0.869, and revealed that best cut off value for postductal O2 saturation in relation to echocardiographic finding was 92% with S.E = 0.051 and 95% C.I = 0.757 - 0.898
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Critical congenital heart diseases
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Newborns
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pulse oximetry
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Iman Fathy Iskander ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Salma Elhouchi ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wael Attia ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.28.M.Sc.2015.Di.R 01010110068268000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.28.M.Sc.2015.Di.R 01020110068268000 22.09.2023 CD - Rom 68268.CD