header

Comparison of three-dimensional and two-dimensional ultrasound in predicting the presence of nuchal cord prior to delivery / (Record no. 55784)

MARC details
000 -LEADER
fixed length control field 02695cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160330s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.15.M.Sc.2015.He.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hend Mahmoud Abdalghany
245 10 - TITLE STATEMENT
Title Comparison of three-dimensional and two-dimensional ultrasound in predicting the presence of nuchal cord prior to delivery /
Statement of responsibility, etc. Hend Mahmoud Abdalghany ; Supervised Ahmed Abdalmaguid Attia , Ahmed Hussein Alsawaf , Mona Fouad Ahmed
246 15 - VARYING FORM OF TITLE
Title proper/short title المقارنة بين الموجات الصوتية الثلاثية الابعاد والثنائية الابعاد في التنبؤ بوجود الحبل السري حول رقبة الجنين قبل الولادة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hend Mahmoud Abdalghany ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 85 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynaecology and Obstetrics
520 ## - SUMMARY, ETC.
Summary, etc. The Objective: of our study is to compare the accuracy of ultrasonography (2D and 3D) in prediction of presence of nuchal cord prior to delivery. We also measured the impact of nuchal cord on perinatal outcome. Methodology:150 pregnant women above 37 weeks were examined by 2D and 3D US within 24 hours of delivery. Nuchal cord presence at delivery, mode of delivery and early neonatal outcome were recorded. Results:Nuchal cord incidence was 18%. The sensitivity of 2D ultrasound is 37.04 %compared to that of 3D ultrasound which is 55.56%, where the specificity of 2D and 3D ultrasound was 74.8% and 84% respectively.Out of 53 cases (35.33 %) ended pregnancy by cesarean section, only 13 cases had nuchal cord. The incidence of mechonium staining in all cases was thirty cases (2%). Only five cases had nuchal cord at delivery. 43 neonates had 1-min Apgar score {u2039} 7 at delivery (28.67%). Only eight cases had nuchal cord.Out of those 43 cases, 14 cases continued to have an Apgar score {u2039} 7 even after 5-minutes (3 cases delivered with nuchal cord).Conclusion:. The ability to view the nuchal cord is better with three-dimensional sonography than with two-dimensional. A nuchal cord does not appear to affect the mode of delivery or early neonatal outcome
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term 3D US-2D US
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cord around fetal neck
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Nuchal cord
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Abdalmaguid Attia ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Hussein Alsawaf ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mona Fouad Ahmed ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Aml
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.15.M.Sc.2015.He.C 01010110068434000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.15.M.Sc.2015.He.C 01020110068434000 22.09.2023 CD - Rom 68434.CD