Effect of three different implant diameter on the stress induced on supporting structure bone in implant supported over denture : (Record no. 56275)

MARC details
000 -LEADER
fixed length control field 02829cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031502.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160505s2015 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2015.Os.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Osama Ahmed Gaballah
245 10 - TITLE STATEMENT
Title Effect of three different implant diameter on the stress induced on supporting structure bone in implant supported over denture :
Remainder of title Finite element study /
Statement of responsibility, etc. Osama Ahmed Gaballah ; Supervised Hamdi AboElfotouh , Ahmed Emad Fayyad
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير ثلاثه غرسات مختلفة القطر على الاجهاد المتولد على العظم فى الاطقم الفوقيه المدعمة بغرسات
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Osama Ahmed Gaballah ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 150 P. :
Other physical details photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The present study was conducted to evaluate the stress patterns induced in implants and bone surrounding implants in mandibular overdenture with three different diameters using three dimensional finite element analysis. Three different implant diameters were used. A computerized tomographic image was obtained. Three dimensional geometrical models were constructed using data from the computerized tomographic image into solid works program. The implants were virtually installed in the molar and canine region with diameter 2.8mm, 3.7 and 4.8mm. The material properties for each material were identified in the program. Vertical and oblique loads were applied for each model. The models were restrained at the inferior border to avoid total body displacement. All models were meshed and analyzed using a three dimensional finite element iterative solving method for stress analysis under vertical and oblique loading. The maximal Von Misses stresses were recorded and computed. The maximum stresses were recorded with 2.8 mm diameter (mini dental implant), while the least stresses were recorded with 4.8 mm diameter. These findings may be attributed to the different implant diameter. It was found that stresses had been increased due to the decrease in implant diameter. The stress values induced in the peri-implant bone due to the oblique load were greater than those induced by the vertical load
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term implant supported over denture
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Supporting structure bone
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Three different implant diameter
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Emad Fayyad ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hamdi AboElfotouh ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2015.Os.E 01010110068757000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2015.Os.E 01020110068757000 22.09.2023 CD - Rom 68757.CD