Effect of implant platform switching on strain developed around implants with straight and angled abutments / (Record no. 56387)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03030cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031506.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 160511s2015 ua do f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2015.Mo.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mohamed Ahmed Abdelrahman Elsadek |
245 10 - TITLE STATEMENT | |
Title | Effect of implant platform switching on strain developed around implants with straight and angled abutments / |
Statement of responsibility, etc. | Mohamed Ahmed Abdelrahman Elsadek ; Supervised Hesham Abdelmeguid Katamesh , Hanaa Ibrahim Sallam |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تأثير تغيير قطر دعامة الغرسه على الإنفعال الناتج حول الغرسات ذات الدعامات المعتدله و المائله |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mohamed Ahmed Abdelrahman Elsadek , |
Date of publication, distribution, etc. | 2015 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 97 P. : |
Other physical details | charts , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This study was conducted to investigate the effect of implant platform switching on strains developed around implants with straight and angled abutments. Samples of this study were divided into two groups: Group I: (n = 10) ten straight implants with five straight abutments with matching diameter to that of the implant (4.5 mm) (sub- group A) and five straight abutments with platform switched smaller diameter (3.75) than that of the implant.(sub- group B). Group II: (n = 10) ten inclined implants with five 15{u00BA} angled abutments with matching diameter to that of the implant (4.5 mm) (sub- group A) and five 15{u00BA} angled abutments with platform switched smaller diameter (3.75) than that of the implant.(sub- group B). All implants were inserted in epoxy resin blocks with the aid of a specially designed mould and paralleling device following a standardized protocol. The abutments were then screwed to the implants with the hex tool and torque wrench. All abutments received Ni-Cr full metal crowns representing upper premolar with non-anatomical occlusal surface following a standardized protocol. Crowns were cemented on their corresponding abutments using temporary eugenol-free cement. Epoxy resin models were prepared to receive four strain gauges around each implant. Then strain gauges were luted on the prepared epoxy blocks. After connecting the strain gauges to the strain meter, a 300 N load was applied axially on each crown using a universal testing machine at a rate of 1N/sec. The developed microstrains around each implant were recorded using a four channel strain meter |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Angled abutments |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Platform switching |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Strain developed around implants |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hanaa Ibrahim Sallam , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hesham Abdelmeguid Katamesh , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2015.Mo.E | 01010110068903000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2015.Mo.E | 01020110068903000 | 22.09.2023 | CD - Rom | 68903.CD |