header

Effect of implant platform switching on strain developed around implants with straight and angled abutments / (Record no. 56387)

MARC details
000 -LEADER
fixed length control field 03030cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031506.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160511s2015 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2015.Mo.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Ahmed Abdelrahman Elsadek
245 10 - TITLE STATEMENT
Title Effect of implant platform switching on strain developed around implants with straight and angled abutments /
Statement of responsibility, etc. Mohamed Ahmed Abdelrahman Elsadek ; Supervised Hesham Abdelmeguid Katamesh , Hanaa Ibrahim Sallam
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير تغيير قطر دعامة الغرسه على الإنفعال الناتج حول الغرسات ذات الدعامات المعتدله و المائله
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Ahmed Abdelrahman Elsadek ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 97 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to investigate the effect of implant platform switching on strains developed around implants with straight and angled abutments. Samples of this study were divided into two groups: Group I: (n = 10) ten straight implants with five straight abutments with matching diameter to that of the implant (4.5 mm) (sub- group A) and five straight abutments with platform switched smaller diameter (3.75) than that of the implant.(sub- group B). Group II: (n = 10) ten inclined implants with five 15{u00BA} angled abutments with matching diameter to that of the implant (4.5 mm) (sub- group A) and five 15{u00BA} angled abutments with platform switched smaller diameter (3.75) than that of the implant.(sub- group B). All implants were inserted in epoxy resin blocks with the aid of a specially designed mould and paralleling device following a standardized protocol. The abutments were then screwed to the implants with the hex tool and torque wrench. All abutments received Ni-Cr full metal crowns representing upper premolar with non-anatomical occlusal surface following a standardized protocol. Crowns were cemented on their corresponding abutments using temporary eugenol-free cement. Epoxy resin models were prepared to receive four strain gauges around each implant. Then strain gauges were luted on the prepared epoxy blocks. After connecting the strain gauges to the strain meter, a 300 N load was applied axially on each crown using a universal testing machine at a rate of 1N/sec. The developed microstrains around each implant were recorded using a four channel strain meter
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Angled abutments
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Platform switching
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Strain developed around implants
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hanaa Ibrahim Sallam ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hesham Abdelmeguid Katamesh ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2015.Mo.E 01010110068903000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2015.Mo.E 01020110068903000 22.09.2023 CD - Rom 68903.CD