header

Efficacy of digital radiographic techniques in the assessment of jaw bone tissue / (Record no. 58341)

MARC details
000 -LEADER
fixed length control field 03237cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031605.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170105s2015 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.M.Sc.2015.Ah.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Elsayed Mohamed
245 10 - TITLE STATEMENT
Title Efficacy of digital radiographic techniques in the assessment of jaw bone tissue /
Statement of responsibility, etc. Ahmed Mohamed Elsayed Mohamed ; Supervised Hany Mahmoud Omar , Farid Medhat Farid
246 15 - VARYING FORM OF TITLE
Title proper/short title فعالية تقنيات الأشعة الرقمية في تقييم نسيج عظام الفك
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Mohamed Elsayed Mohamed ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 195 P. :
Other physical details charts , facsimiles , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology)
520 ## - SUMMARY, ETC.
Summary, etc. Materials and Methods: Five dry human adult mandibles of unknown age or gender were used in our study. Gutta-percha was used as radio-opaque markers to verify the correct sites of the mental, mandibular and lingual foramina in radiographs. The mandibles{u2019} outer surfaces were covered by pink set up modeling wax in order to simulate soft tissues. Radiographic indices and linear measurements obtained from the different digital imaging modalities were compared with the direct real measurements performed by using 0.01 mm precision vernier digital caliper. Direct measurements of the mandibles were considered the gold standard. Measurements were obtained separately from the right and left mandibular sides ending up with ten evaluated samples. All direct real and digital radiographic measurements were obtained in millimeters. Results: "Excluding M/M index and M/M index half MF". There was no statistically significant difference between all indices measurements{u2019} means and the real ones. Regarding linear measurements; Most of linear measurements{u2019} means showed no statistically significant underestimation; except superior R.O. point to the lower border of the mandible which was significantly underestimated in the digital, auto and manual reformatted panoramic. Meanwhile, superior R.O. point to the upper border of the mandible was significantly overestimated in manual reformatted panoramic. Conclusion: There was no statistically significant difference between most of linear & indices measurements{u2019} means and the real ones. Radiation dose to patients must be concerned. Conventional digital panoramic radiographs must not be replaced by CBCT images, but CBCT should be taken only if there is a clear indication. M/M index is mostly used to assess the level of bone resorption. In our study M/M index and M/M index half MF were statistically significant overestimated when measured in all modalities in our study. Thus shown to be unreliable
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CBCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Digital panoramic
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term PSP
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Farid Medhat Farid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hany Mahmoud Omar ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.M.Sc.2015.Ah.E 01010110070036000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.M.Sc.2015.Ah.E 01020110070036000 22.09.2023 CD - Rom 70036.CD