A wearable device for monitoring and prevention of repetitive ankle sprain injuries / (Record no. 58409)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03182cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031607.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 161111s2016 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.13.03.M.Sc.2016.Mo.W |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mohammed Abdalla Mohammed Attia |
245 12 - TITLE STATEMENT | |
Title | A wearable device for monitoring and prevention of repetitive ankle sprain injuries / |
Statement of responsibility, etc. | Mohammed Abdalla Mohammed Attia ; Supervised Ayman M. Eldeib , Mona F. Taher , Aliaa Rehan Youssef |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | جهاز يمكن ارتداءه فى القدم لرصد ومنع تكرار التواء الكاحل |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mohammed Abdalla Mohammed Attia , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 71 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Systems and Biomedical Engineering |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Ankle sprain is one of the most common injuries in sports. It may occur during regular functional activities and may result in an unstable ankle joint. Repeated incidences of ankle sprain may be complicated with chronic ankle instability (CAI), which, if not treated, can lead to permanent ligament damage and impairment of normal gait. In an effort to avoid such consequences, ongoing research has investigated methods for protecting the ankle and preventing the occurrence of ankle sprain. This study addresses prevention of recurrent ankle sprain by presenting the design and implementation of a smart wearable device that can predict, and hence, prevent the occurrence of ankle sprain. The proposed device prevents ankle ligamentous injury by electrical stimulation of the peroneal muscles using surface electrodes causing dorsiflexion of the foot. Prediction of potentially harmful motion is achieved by continuous monitoring of ankle kinematics using inertial motion sensors. Laboratory testing of the device showed that it has a fast response time of eight msec, which enables prevention of ankle sprain before ligament damage occurs. Testing also showed an accuracy of 96% in detection and taking corrective action of motion that predisposes to ankle sprain (plantar flexion and inversion). Wireless communication between the components of the device, in addition to its small size, low cost and low power consumption, makes it unobtrusive, easy to wear without hindering regular functional activities. The device connects via Bluetooth to an android smart phone application for continuous data logging and reporting to keep track of the incidences of possible ankle sprain motion and its correction. Future work is recommended to test the clinical effectiveness of the proposed device in patients with CAI |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Ankle sprain |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Functional Electrical Stimulation |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | MEMS |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Aliaa Rehan Youssef , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ayman M. Eldeib , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mona F. Taher , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Shaima |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.13.03.M.Sc.2016.Mo.W | 01010110069995000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.13.03.M.Sc.2016.Mo.W | 01020110069995000 | 22.09.2023 | CD - Rom | 69995.CD |