Effect of new design (Bullard) versus conventional telescopic crown on bone level (radiographically) of implant-retained mandibular overdenture / (Record no. 58776)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03156cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031618.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 161126s2015 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.09.M.Sc.2015.Ma.E |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Marco Fouad Khalil Galoaa |
245 10 - TITLE STATEMENT | |
Title | Effect of new design (Bullard) versus conventional telescopic crown on bone level (radiographically) of implant-retained mandibular overdenture / |
Statement of responsibility, etc. | Marco Fouad Khalil Galoaa ; Supervised Nadia Ahmed Abbas , Mohammed Farouk Abdullah |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | تأثير تصميم حديث(البولارد) والتاج التليسكوبي التقليدي علي المستوي العظمي للغرسة الداعمة للطقم الفوقي السفلي (اشعاعيا |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Marco Fouad Khalil Galoaa , |
Date of publication, distribution, etc. | 2015 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 79 P. : |
Other physical details | facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This study was performed to compare the effect of of new design (Bullard) versus conventional telescopic crown on bone level (radiographically) of implant-retained mandibular overdenture The study was carried out on twenty completely edentulous patients, with two interforaminally installed implants, on both canine regions. The first group received the resilient Bullard telescopic retainers and the second group received the rigid conventional telescopic retainers. In the first group,Bullard telescopic retainers were designed using Plastic castable patterns were screwed to the analogues, waxed up with milling wax and milled with milling machine to form 6 degree convergence, and then a castable retentive cap was retained to the burnout plastic abutments with wax, to form the primary crowns. The retentive cap has the same diameter as the implant platform. In the other group, conventional telescopic implant retained mandibular overdenture. Plastic castable patterns were screwed to the analogues, waxed up with milling wax and milled with milling machine then casted and screwd in the implant octa abutments, as a primary copings the secondary copings costructerd over its and connected by a framework inserted in fitting surface of the denture. At the time of loading, amount of bone loss of both groups were tested using the digital xray with aiding of the software of Digora to testing the amount of bone loss.After the interval of three months, patients of both groups were recalled and the amount of bone loss was measured. The same was done after the interval of six months as well. After finishing the amount of bone loss finally; the collected data was tabulated and statistically analyzed |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Bullard |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Radiographically |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Telescopic crown |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohammed Farouk Abdullah , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Nadia Ahmed Abbas , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Soheir |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.09.M.Sc.2015.Ma.E | 01010110070374000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.09.M.Sc.2015.Ma.E | 01020110070374000 | 22.09.2023 | CD - Rom | 70374.CD |