header

Additive role of 3D digital breast tomosynthesis versus ultrasonography in the evaluation of breast asymmetries / (Record no. 59135)

MARC details
000 -LEADER
fixed length control field 02972cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031629.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161224s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2015.Em.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Eman Mohamed Nagib Mostafa
245 10 - TITLE STATEMENT
Title Additive role of 3D digital breast tomosynthesis versus ultrasonography in the evaluation of breast asymmetries /
Statement of responsibility, etc. Eman Mohamed Nagib Mostafa ; Supervised Rasha Mohammed kamal Eldin , Omnia Mokhtar Nada , Shaimaa Farouk Lasheen
246 15 - VARYING FORM OF TITLE
Title proper/short title الدور الاضافي للتصويربالماموجرام متعدد المقاطع والموجات فوق الصوتية في تقييم حالات عدم التماثل بالثدي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Eman Mohamed Nagib Mostafa ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 130 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Mammography is the best-studied breast cancer screening modality and the only recommended imaging tool for screening the general population. Full field digital mammograghy (FFDM) is accused of having a low sensitivity because the overlapping breast tissue may hide an abnormality and this increases the number of false negative results. On the other hand, it is accused of having a low specificity because the overlapping tissues may give the impression of a false abnormality which is responsible for a large number of false positive results. 3D Digital Tomosynthesis resolve the problem of tissue overlap in FFDM. It enhances the detection and diagnostic ability of FFDM. Breast Ultrasound has an established role in the characterization of the asymmetric lesions and in further evaluation of abnormalities identified on other breast imaging modalities. It provides information on the internal matrix, shape, margins, and vascular patterns of mammograghic asymmetric breast findings that help to differentiate benign from malignant masses with a fairly high degree of certainty. Ultrasound is the preferred initial imaging technique for evaluating symptomatic breast lesions in women younger than 30years. Aim of work: To evaluate the diagnostic value of Digital Breast Tomosynthesis ( DBT) versus US in the evaluation of breast asymmetries regarding the abstract and key words VIII sensitivity, specificity, the positive predictive value, the negative predictive value and the accuracy
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Breast asymmetries
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Digital breast tomosynthesis ( DBT)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term US
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omnia Mokhtar Nada ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rasha Mohammed kamal Eldin ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Shaimaa Farouk Lasheen,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shaima
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2015.Em.A 01010110070509000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2015.Em.A 01020110070509000 22.09.2023 CD - Rom 70509.CD