header

Nerve conduction study versus sonography in carpal tunnel syndrome / (Record no. 59158)

MARC details
000 -LEADER
fixed length control field 02744cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031630.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161225s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.36.M.Sc.2015.Ay.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Aya Salah Ahmed Agamy
245 10 - TITLE STATEMENT
Title Nerve conduction study versus sonography in carpal tunnel syndrome /
Statement of responsibility, etc. Aya Salah Ahmed Agamy ; Supervised Hala Rashad Elhabashy , Reem Atef Elhadidy , Basma Bahgat Elsayed
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة دراسة رسم الأعصاب بالموجات الصوتيه فى متلازمة اختناق العصب الأوسط الرسغى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Aya Salah Ahmed Agamy ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 123 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Neuro Physiology
520 ## - SUMMARY, ETC.
Summary, etc. This work is intended to compare the diagnostic value of nerve conduction studies with high-resolution ultrasound in carpal tunnel syndrome and to answer if ultrasound can safely replace the presently applied and accepted electrodiagnostic confirmation of the clinical diagnosis of CTS.Methods 60 wrists of patients with clinically and electrophysiologically defined CTS were enrolled, along with the same number of age- and sex matched controls. All patients and controls were subjected to clinical assessment , sonographic measurement of the cross-sectional area (CSA) of the median nerve and nerve conduction studies (NCS). Sensitivity and specificity of ultrasound was obtained and its ability in diagnosing CTS was assessed. Results There were no significant differences in age and gender between patients and controls (p{uF03E} 0.05). The CSA at the tunnel inlet was significantly larger in patients than in controls (p= 0.001). It is noted that the US sensitivity is high in differentiating the patients from the control subjects and between early CTS from controls, but it is low in differentiating early CTS from mild and mild from moderate CTS. Conclusion our study shows that both NCS and US help the diagnosis of CTS and supports the use of US as a screening tool for detection of CTS and as a complementary test to NCS ,but it cannot replace the NCS
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Carpal tunnel syndrome (CTS)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Nerve conduction studies (NCS)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ultrasonography
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Basma Bahgat Elsayed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hala Rashad Elhabashy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Reem Atef Elhadidy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.36.M.Sc.2015.Ay.N 01010110070520000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.36.M.Sc.2015.Ay.N 01020110070520000 22.09.2023 CD - Rom 70520.CD