Improvement in early detection of breast cancer / (Record no. 59542)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01868cam a2200325 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031642.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170122s2016 ua d f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.12.04.M.Sc.2016.Es.I |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Esraa Osama Zaki Ellewaa |
245 10 - TITLE STATEMENT | |
Title | Improvement in early detection of breast cancer / |
Statement of responsibility, etc. | Esraa Osama Zaki Ellewaa ; Supervised Ali Ellakkani |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | {uFE97}{uFEA4}{uFEB4}{uFBFF}{uFEE6} ا{uئإؤئ}{uئإؤأ}{uئإآ٨}{uئإؤ٢} ا{uئإؤئ}{uئإإ٤}{uئإ٩٢}{uئإؤأ}{uئإءإ} {uئإؤئ}{uئإآ٤}{uئإءإ}{uئإأ٣}{uئإ٨إ}ن ا{uئإؤئ}{uئإ٩أ}{uئإءء}ى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Esraa Osama Zaki Ellewaa , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 48 P. : |
Other physical details | charts ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This work introduces a theoretical method which can restore some of the low energy x- ray photons that do not reach the detector due to the breast attenuation and that will increase the quality of the processed mammography image. This is performed by measuring the incident x- ray tube spectrum, the transmitted x- ray spectrum through the breast and the thickness of the imaged breast then extrapolating the attenuation coefficient toward the low energy region. As a result the optimum energy weighting SNR was enhanced for the two different x-ray spectra with and without Mo filter about 36% and 46% respectively |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Digital detectors |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Energy weighting SNR |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Mammography |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Ali Ellakkani , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.04.M.Sc.2016.Es.I | 01010110070774000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.04.M.Sc.2016.Es.I | 01020110070774000 | 22.09.2023 | CD - Rom | 70774.CD |