Diagnostic accuracy of cone beam computed tomography versus low dose computed tomography : (Record no. 59885)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02577cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031651.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170218s2015 ua h f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.Ph.D.2015.Ha.D |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Hagar Mohamed Elsarawy |
245 10 - TITLE STATEMENT | |
Title | Diagnostic accuracy of cone beam computed tomography versus low dose computed tomography : |
Remainder of title | In vitro study / |
Statement of responsibility, etc. | Hagar Mohamed Elsarawy ; Supervised Hoda Abdelkader Saleh , Sherouk Hassan Ali Khalifa |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | الدقة التشخيصية للأشعة المقطعية بالحاسوب مخروطية الشعاع مقابل الأشعة المقطعية بالحاسوب ذات الجرعة الاشعاعية القليلة : |
Remainder of title | دراسة مختبرية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Hagar Mohamed Elsarawy , |
Date of publication, distribution, etc. | 2015 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 142 P. : |
Other physical details | facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | This study was designed to compare the accuracy of low dose CT versus CBCT in assessment of the various maxillofacial linear measurements. Methods: 8 skulls were included in this study and 11 linear skull measurements were selected. Direct bone measurements were obtained using digital caliber then skulls were imaged once using CBCT standard protocol and 3 times with 16 slices MDCT using three low dose protocols with reduced mAs values (40, 50, 60 mAs). Mean absolute error for each whole protocol was obtained and the degree of over and underestimation for each protocol was recorded. Results: or CBCT protocol the mean absolute error was 0.167 ± 0.6461mm while for the MDCT protocols it was 0.632 ± 0.9803, 0.320 ± 0.8393, 0.166 ± 0.803mm For the first, second and third protocol respectively. First and second protocols showed a tendency for overestimation while the third MDCT protocol and CBCT protocol showed a tendency for underestimation. But all were within the range of 1mm. Conclusions: Low dose MDCT accuracy is less than that of CBCT but the difference between the two techniques is still not significant in some protocols |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Accuracy |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | CBCT |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Low dose CT |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hoda Abdelkader Saleh , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Sherouk Hassan Ali Khalifa , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.Ph.D.2015.Ha.D | 01010110071101000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.Ph.D.2015.Ha.D | 01020110071101000 | 22.09.2023 | CD - Rom | 71101.CD |